Napoleon BGNV40-N Скачать руководство пользователя страница 1

1

               W415-0320 / D / 01.06.07

W415-0320 / D / 01.16.07

Содержание BGNV40-N

Страница 1: ...1 W415 0320 D 01 06 07 W415 0320 D 01 16 07...

Страница 2: ...2 W415 0320 D 01 06 07 WHAT TO DO IF YOU SMELL GAS WARNINGS SAFETY PRECAUTIONS...

Страница 3: ...ace should be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near the fireplace Any safety screen or guard removed for ser...

Страница 4: ...fficial Labour costs to the however requires the prior approval of an authorized company official Labour costs to the account of account of account of account of account of NAPOLEON NAPOLEON NAPOLEON...

Страница 5: ...laced in front of the fireplace must be kept a minimum of 48 away from the glass front faces of the unit FOR YOUR SATISFACTION ALL BURNER ASSEMBLIES HAVE BEEN TEST FIRED TO ASSURE THEIR OPERA TIONS AN...

Страница 6: ...6 W415 0320 D 01 06 07 DIMENSIONS OPEN END SEE THRU PENINSULA ISLAND FIGURES1a d...

Страница 7: ...stat This thermally activated switch located in front of the draft hood senses an increase in temperature and acts as a safety shut off See A below It shuts down the gas to the main burner in the unli...

Страница 8: ...place after it is positioned and the vent system is installed Use 2x4 s and frame to local building codes FIGURE 6 To install the fireplace face flush with the finished wall position the framework to...

Страница 9: ...ng hard wood which if not planned for will interfere with the opening of the lower access door and the installation of many decorative flashing accessories Objects placed in front of the fireplace sho...

Страница 10: ...or ceramic tile may protrude in these areas It is not necessary to install a hearth extension with this fireplace system When roughing in the fireplace raise the fireplace to ac commodate for the thi...

Страница 11: ...n bend down the tab to secure DE TAIL 6 RETAINER RETAINER STEP5 STEP6 DETAIL5 6 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face ar...

Страница 12: ...ny decorative flashing accessories Objects placed in front of the fireplace should be kept a minimum of 48 away from the glass front faces Refer to pages 14 17 for complete instructions regarding mant...

Страница 13: ...ocated on the gas valve and the other lead to the vent safety switch wire located loose in the valve compartment See FIGURE 3 Do not connect either the wall switch thermostat or gas valve to electrici...

Страница 14: ...a non com bustible material FIGURE24 Dashed lines are suitable mantle sizes and clearances when a non combustible facing is used SEE FIGURE 9 FINISHING MANTLE INSTALLATION When using a non combustibl...

Страница 15: ...3a is the base of log 3 The base sits diagonally in the designated area lo cated between logs 1 and fits tight up against 2 4 The slot in the under side of piece 3b fits over 3a Place the end of piece...

Страница 16: ...ace Tear the embers into small pieces and place on the ported area of the burner Care should be taken to shred the embers into thin small irregular pieces as only the exposed edges of the fibre hairs...

Страница 17: ...heat ing glass break age and or dis colouration of the upper trim To install the door s hook it over the steel lip located above the door opening Secure with screws along the bottom of the door Tighte...

Страница 18: ...ximately 10 minutes after lighting the fireplace and will run for approximately 30 45 minutes after the fireplace has been turned off Use of the fan increases the output of heat in accordance with loc...

Страница 19: ...to burn repeat steps 3 through 5 7 With pilot lit depress and turn gas knob counter clock wise to on 8 If equipped with remote on off switch thermostat main burner may not come on when you turn valve...

Страница 20: ...g Opening the air shutter will cause a more blue flame but can cause flame lifting from the burner ports The flame may not appear yellow immediately al low 15 to 30 minutes for the final flame colour...

Страница 21: ...EZO IGNITER 40 N455 0003 MAIN BURNER ORIFICE PROPANE REPLACEMENTS When ordering replacement parts always give the follow ing information 1 MODEL SERIAL NUMBER OF FIREPLACE 2 INSTALLATION DATE OF FIREP...

Страница 22: ...22 W415 0320 D 01 06 07 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 23: ...R PLATED 9 GOIBG 1 GOTHIC ORNAMENTAL INSET BRUSHED GOLD PLATED 10 EGOIG 1 END GOTHIC ORNAMENTAL INSET GOLD PLATED 10 EGOIKG 1 END GOTHIC ORNAMENTAL INSET BLACK GOLD PLATED 10 EGOIBC 1 END GOTHIC ORNAM...

Страница 24: ...blocked or disconnected Correct See Figure 2 Unit has overheated See Figure 2 Pilot goes out when the gas knob is re leased The gas valve has an interlock device which will not allow the pilot burner...

Страница 25: ...or propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLYTO RESEAL DO NOT OVERTORQUE Leak test with a soap and water solution Unit is...

Страница 26: ...26 W415 0320 D 01 06 07 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 27: ...NOTES...

Страница 28: ...28 W415 0320 D 01 06 07 NOTES...

Отзывы: