Napoleon BGNV36N Скачать руководство пользователя страница 1

1

W415-0275 / C / 09.23.05

R-2000

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.22, AND ANSI Z21.50 RESPECTIVELY FOR VENTED GAS FIREPLACES.

MILLIVOLT SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS FOR

VENTED GAS FIREPLACE

NATURAL GAS 

 MODEL

 

BGNV36N

PROPANE GAS  

MODEL

 

BGNV36P

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS

WARNING: 

 If the information in these instructions is not followed exactly, a fire or

explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of

this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

•  Do not try to light any appliance.
•  Do not touch any electrical switch.
•  Do not use any phone in your building.

• Immediately call your gas supplier from

a neighbour's phone. Follow the gas
supplier's instructions.

•  If you cannot reach your gas supplier, call

the fire department.

Installation and service must be performed by a qualified installer, service agency or
the gas supplier.

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031

www.napoleonfireplaces.com • [email protected]

Содержание BGNV36N

Страница 1: ...ot store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Страница 2: ...is fireplace be modified This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this fireplace if any part has been under water Immediat...

Страница 3: ...designed with superior components and materials assembled by trained craftsmen who take great pride in their work The burner and valve assembly are leak and test fired at a quality test station The co...

Страница 4: ...rviced by a qualified installer to conform with local codes Installation practices vary from region to region and it is important to know the specifics that apply to your area for example in Massachus...

Страница 5: ...temperature and acts as a safety shut off See A below It shuts down the gas to the main burner in the unlikely event of the unit overheating The HI Limit switch will automatically reset after the uni...

Страница 6: ...is complete 1 Move the fireplace into position and secure using the nailing tabs and or secure to the floor through the 1 4 holes located at either end of the base 2 Route a 3 8 N P T black iron gas l...

Страница 7: ...tab vertically on the cor ner post Figure 12 a Drill through the centre of the top and bottom slots in the nailing tab Secure using the two sheet metal screws supplied This allows the nailing tab to s...

Страница 8: ...irebox using three screws DOOR LATCH UPPER LOUVRE FLANGE CLIP FIGURE13 LOWER LOUVRES VALVE CONTROLDOOR LOUVRE HOOD SLOT BRACKET FINISHING DOOR OPENING CLOSING GVFL LOUVRE INSTALLATION FIGURE14 FIGURE1...

Страница 9: ...sition lining up the studs located on the burner with the holes on the bottom of the logs Ensure that the small logs sit flat on the burner 3 Place the bottom of the left crossover log 4 against the l...

Страница 10: ...e taken to prevent drywall dust from coming into contact with the blower or its compartment Any damage resulting from this condition is not cov ered by the warranty policy A B INSTALLATION TO BE DONE...

Страница 11: ...he current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States The wire harness provided in this kit is a universal har ness When installed e...

Страница 12: ...fireplace 3 Turn the gas knob clockwise to off 4 Wait five 5 minutes to clear out any gas If you smell gas including near the floor Stop Follow B in the above safety information on this label If you d...

Страница 13: ...ck to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on A 5 to 10 second total light up period is satisfactory If ignition takes longer consult...

Страница 14: ...AL INSETS BLACK GOLD PLATED 39 HOIBC 1 HERITAGE ORNAMENTAL INSETS BRUSHED COPPER PLATED 39 HOIBG 1 HERITAGE ORNAMENTAL INSETS BRUSHED GOLD PLATED 40 DOIG 1 DIAMOND ORNAMENTAL INSETS GOLD PLATED 40 DOI...

Страница 15: ...15 W415 0275 C 09 23 05...

Страница 16: ...cked or disconnected Correct See Figure 2 Unit has overheated See Figure 2 Pilot goes out when the gas knob is re leased The gas valve has an interlock device which will not allow the pilot burner to...

Страница 17: ...or 10 water column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVERTORQUE Leak test with a soap and wa...

Страница 18: ...18 W415 0275 C 09 23 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 19: ...19 W415 0275 C 09 23 05 NOTES...

Страница 20: ...20 W415 0275 C 09 23 05 NOTES...