Napoleon BGD90NT Скачать руководство пользователя страница 1

1

W415-0580 / B / 03.12.08

$10.00

INSTALLATION AND

OPERATION INSTRUCTIONS

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada 

 (705)721-1212 

 fax(705)722-6031

www.napoleonfireplaces.com 

 [email protected]

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACES.

BGD90NT

NATURAL GAS

BGD90PT

PROPANE

If the information in these instructions are 
not followed exactly, a fire or explosion 
may result causing property damage, 
personal injury or loss of life.

- Do not store or use gasoline or other flammable 
vapors and liquids in the vicinity of this or any other 
appliance.

- WHAT TO DO IF YOU SMELL GAS:

 

Do not try to light any appliance.

 

Do not touch any electrical switch; do not use 

 

any phone in your building.

 

Immediately call your gas supplier from a

 

neighbour’s phone.  Follow the gas supplier’s 

 instructions.
 

If you cannot reach your gas supplier, call the fire 

 department.
- Installation and service must be performed by a 
qualified installer, service agency or the supplier.

SAFETY INFORMATION

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

INSTALLER:

 LEAVE THIS MANUAL WITH THE APPLIANCE

CONSUMER:

 RETAIN THIS MANUAL FOR FUTURE REFERENCE

!

WARNING

W415-0580 / B / 03.12.08

Содержание BGD90NT

Страница 1: ...e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch...

Страница 2: ...e fireplace should be located out of traffic and away from furniture and draperies Ensure you have incorporated adequate safety measure to protect infants toddlers from touching hot surfaces Even afte...

Страница 3: ...his limited warranty further does not cover any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chip ping on porcelain enamel parts mechanical bre...

Страница 4: ...EARANCES See the section FRAMING See the section VENTING and IN STALLATION Side Wall See the section FRAMING See the section FRAMING and MINIMUM MANTEL AND ENCLOSURE CLEARANCES for Drywall or other co...

Страница 5: ...ity clearance for servicing and operating the fireplace Never obstruct the front opening of the fireplace Objects placed in front of the fireplace must be kept a minimum of 48 from the front face of t...

Страница 6: ...nimum rise per foot Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed Do not allow the inside liner to bunch up on horizontal or vertical runs...

Страница 7: ...ceptable FIGURE 5 90 H1 V2 H2 V1 HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable values for HT and VT for the following symbols used in the venting ca...

Страница 8: ...1 HT 4 2 VT Formula 2 HT VT 24 75 feet Example 2 Example 3 V1 4 ft V2 1 5 ft VT V1 V2 4 1 5 5 5 ft H1 2 ft H2 1 ft H3 1 ft H4 1 5 ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows 90 03 360 90...

Страница 9: ...uration is unacceptable Formula 2 HT VT 40 feet 20 6 40 Since only formula 2 is met this vent con guration is unacceptable and a new replace location or vent con guration will need to be established t...

Страница 10: ...10 W415 0580 B 03 12 08 MINIMUM AIR TERMINAL LOCATION CLEARANCES FIGURE 12...

Страница 11: ...E THE CORRECT HEIGHT CAULKING FIRESTOP ASSEMBLY VENT SHIELD FINISHING MATERIAL 14 1 2 FIGURE 13 VERTICAL INSTALLATION This application occurs when venting through a roof Installation kits for various...

Страница 12: ...TICAL AIR TERMINAL INSTALLATION 1 Move the fireplace into position 2 Fasten the roof support to the roof using the screws provided The roof support is optional In this case the venting is to be adequa...

Страница 13: ...the mobile home appliance MOBILE HOME This Mobile Manufactured Home Listed appliance comes factory equipped with a means to secure the unit The fireplace is equipped with two 1 4 diameter holes locat...

Страница 14: ...14 W415 0580 B 03 12 08 59 1 4 1 MIN 1 MIN 116 82 FIGURE 25 FIGURE 28 59 1 4 29 1 2 29 1 2 10 MIN 59 1 4 FIGURE 26 FIGURE 27...

Страница 15: ...e nishing Front 5 1 2 to sides of replace opening Front 5 1 2 to sides of replace opening 23 3 4 to top of replace opening 23 3 4 to top of replace opening See Venting Section See Venting Section It i...

Страница 16: ...losure requires the replace junction box to be hard wired This replace must be electrically connected and grounded in ac cordance with local codes In the absence of local codes use the current CSA C22...

Страница 17: ...the thick side of the gasket facing up 3 Bend the glass retainers located along the edge of the door frame over the gasket holding the glass in place Careful not to break the glass GLASS DOOR REPLACE...

Страница 18: ...al use the panels will darken temporarily The appearance of the panels will permanently lighten in colour with use INSTALL PANELS IN THE FOLLOWING ORDER RETAINER Secure the Left Panel and Right Panel...

Страница 19: ...ff of log 7 2 Place log 2 and log 3 onto the locating pins The logs should sit at on the burner 3 Place the locating hole on the underside of log 4 onto the locating pin on top of log 3 The notch at t...

Страница 20: ...event the lamps or lens need replacing follow these instructions Shut off breaker at main power supply Remove the four screws that secure the lens frame to the Firebox top This frame retains the glass...

Страница 21: ...and thermocouple 6 Remove screws securing gas valve to the mounting bracket VALVE REMOVAL 1 Open the right control door by pulling bottom portion away from magnet catch 2 Remove the hearth strip by li...

Страница 22: ...itialized TEMPERATURE DISPLAY 1 Press the ON OFF key on the transmitter The transmitter display will show all active icons on the screen At the same time the receiver connects the thermopile to the ga...

Страница 23: ...levels With the system on and the ame level at the maximum press the Down Arrow Key once and it will reduce the ame height by one step until the ame is turned off The Up Arrow Key will increase the am...

Страница 24: ...rmostat function to control the replace during a power failure The blower and night light features will not operate during a power failure The receiver will emit a beep sound to con rm programming has...

Страница 25: ...t follow these instruc tions exactly a re or explosion may result causing property damage personal injury or loss of life Initial lighting of the pilot and main burners must be done with the glass doo...

Страница 26: ...ches toward the burner with the third jet 5 Replace the cleaned logs 6 Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on A 5 to 10 seco...

Страница 27: ...peci cally approved with this appliance may result in property damage or personal injury WARNING WARNING PART NO DESCRIPTION 1 W390 0002 DOOR LATCH EA 2 W725 0047 NATURAL GAS VALVE MODULATING 2 W725 0...

Страница 28: ...28 W415 0580 B 03 12 08 6 4 8 7 5 41 23 28 29 30 31 35 27 26 34 64 33 66 32 11 65 21 2 15 16 12 3 14 19 17 71 55 58 22 79 63 69 70 13...

Страница 29: ...pattern around the thermocouple Pilot ame is not engul ng the thermocouple Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace thermocouple re...

Страница 30: ...t will not light check if pilot can be lit by a match check that the wire is connected to the spark module check batteries replace the wire if the wire insulation is broken or frayed replace the elect...

Страница 31: ...31 W415 0580 B 03 12 08 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...

Страница 32: ...32 W415 0580 B 03 12 08 NOTES...

Отзывы: