 SLE Commercial LTEVI & LTEAI Series Dual-Path Alarm Communicators -- Installation Instructions

 

(STARLINK RADIO HOUSING) 

StarLink Radio Terminals

 

LOCAL 

DOWNLOAD  

TELCO  

SECONDARY 

TELCO  

PRIMARY 

ETHERNET 

(+) 

(

POWER  PGM3  IN1 

IN2 

IN3 

(

(+) 

(+) 

(

(

(+) 

(+) 

10 

(

12 

(

11 

(

+

13 

EGND 

19 

N/O 

21 

N/C 

20 

IN4 

IN5 

OUT1 

22 

N/

C

 

24 

N/

O

 

23 

OU

T2

 

Wiring Diagram for GEMC-32, GEMC-96,  

GEMC-128 and GEMC-255 Control Panels 

(CONTROL PANEL HOUSING) 

** 

 

GEMC Control Panel  

PC Board 

Refer to section "

SUPPLYING POWER

". 

*

Not required if 

JP2 

shunt is removed and FACP 

monitors TELCO 2. 

**

Program only TELCO 1 supervision. 

 

Note:

  Connect IN2 to a panel output 

used for identifying Telco line cut (this is 

the DACT interconnect wiring to the radio). 

PC Board:  All connections are power limited except AC Mains and battery terminals. 

 

 

 

 

 

 

Or use a 

12V/24V UL 

Listed 

monitored 

power supply 

10k

 

10k

 

10k

 

 

 

EOLR 

Requires all 8 wires in 

the RJ-45 cable 

JP1 

Shunt 

JP1

 

on top 2 pins 

 

 

(Optio

na

l, f

or r

emot

co

mmunic

at

ion

 

 

 

 

JP2 

Remove 

JP2 

to 

enable TELCO2 

trouble on 

Communicator trouble 

To Panel Zone 

Dedicated to Radio 

Trouble

*

 

Содержание StarLink SLE-LTEVI Series

Страница 1: ...ential Fire alarm capture radio IP communicators are fully supervised wireless digital two way subscriber units All models are compatible with most 12 24VDC alarm control panels always adhere to the d...

Страница 2: ...Smart Channel input Active high input for wiring to the control panel bell output When this input detects a pulsing temporal 3 high it sends a Fire alarm a pulsing temporal 4 CO Alarm a CO alarm is se...

Страница 3: ...or wet contacts TB22 N O OUT2 Normally open Dry contact Form C relay TB23 C OUT2 Common Dry contact Form C relay Relay rated 30V AC DC 500mA TB24 N C OUT2 Normally closed Dry contact Form C relay LED...

Страница 4: ...ded on the premises then only 4 hours of UPS backup are required JUMPER DESCRIPTIONS Jumper block labeled X5 from top to bottom as detailed in the table below Note Contact ID is always available in re...

Страница 5: ...s STEP 2 SELECT A MOUNTING LOCATION The mounting location should be indoors within the protect ed area and selected based on RF performance It is HIGHLY recommended that the installer carefully adhere...

Страница 6: ...ly trouble output relay to the two terminals of the control panel zone dedicated to the trouble With the GEMC Commercial Fire control panels use the dry contacts of the Power Supply relay by removing...

Страница 7: ...apcoNOC com to enable Tip Ring Wiring Fault Report Refer to wiring diagram Supervision Time Schedule Considerations If a status change alarm trouble etc is transmitted the radio supervision timer is r...

Страница 8: ...8 StarLink SLE Commercial LTEVI LTEAI Series Dual Path Alarm Communicators Installation Instructions This page intentionally left blank...

Страница 9: ...ition maintain a minimum 1 4 separation of all primary wiring in the transformer compartment from the yellow secondary wires of the transformer Remove shunt J2 to isolate relay OUT1 common from ground...

Страница 10: ...C 20VA transformer Optional if not used connect 10K resistor between terminals 9 and 10 IN4 StarLink BATTERY RED BLACK 8 9 10 N C COM N O J2 Note Battery leads are not power limited 10k 10k 10k TELCO...

Страница 11: ...s 1 and 2 observing polarity 10k 12V or 24V AUX PWR 10k 10k Refer to section SUPPLYING POWER DO NOT USE EOLR EOLR J2 jumper off This connection only used with Power Supply SLE ULPS R These connections...

Страница 12: ...ol Panel PC Board Refer to section SUPPLYING POWER Not required if JP2 shunt is removed and FACP monitors TELCO 2 Program only TELCO 1 supervision Note Connect IN2 to a panel output used for identifyi...

Страница 13: ...telephone connections primary and secondary for supervision and central station reporting through the StarLink SLE LTEVI FIRE radio By removing the JP2 shunt and enabling the feature Tip Ring Wiring F...

Страница 14: ...that opening the enclosure door will cause a tamper alarm Wiring a normally closed sensor loop for tamper supervision wire to a zone on the control panel GEM Tamperkit consists of Description QTY SC2...

Страница 15: ...TRF12 T123 TRANSFORMER FOR CONNECTION TO SLE CHARGER BOARD UL LISTED SURFACE OR FLUSH MOUNT OUTLET BOX AND NON SWITCHED RECEPTACLE WALL TRANSFORMER SECONDARY WIRING CONDUIT LIMITED TO 20 FEET MAXIMUM...

Страница 16: ...ay not be compromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all c...

Отзывы: