NAPCO StarLink SLE-LTEVI Series Скачать руководство пользователя страница 1

StarLink

 SLE Commercial LTEVI & LTEAI Series Dual-Path Alarm Communicators -- Installation Instructions 

 

ADDITIONAL COMPONENTS 

  In addition to the models listed above, the following sub-

assemblies are available: 

SLE-ULPS-R 

- Power Supply.  Required for installations 

where the control panel cannot provide the Auxiliary 

power required to operate the StarLink radio.  Uses a 

standard 4AH / 12V minimum (7AH maximum, required 

with optional Wi-Fi Module) rechargeable battery to pro-

vide radio standby power.  Requires connection to either 

the model NAPCO TRF12/T123 (16.5V / 20VA) external 

plug-in transformer or the chassis-mounted 16.5VAC / 

20VA transformer affixed inside the housing (see wiring 

diagrams further in this manual).  

Note:  

For models 

without the SLE-ULPS-R, connect the radio terminals 1 

and 2 to the control panel Aux Power terminals 

(observing polarity). 

SLE-WIFI-MODULE

 - Allows your Napco StarLink

 device 

to connect to the Internet by means of a wireless (Wi-Fi) 

link, eliminating a wired Ethernet cable connection.  

Note:

  7AH battery required when using the 

SLE-

WIFI-MODULE

.  For more information, see WI2191. 

SLE-DLCBL

 -  Download Cable, 6 feet 

SLE-ANTEXT30

 - Extended antenna with 30 feet of cable 

SLE-ANTEXT50

 - Extended antenna with 50 feet of cable 

SLE-ANTEXT75

 - Extended antenna with 75 feet of cable 

SLE-ANTEXT100

 - Extended antenna with 100 feet of cable 

  (Any suitable external cellular antenna is permitted by 

UL).  Always follow the manufacturer's installation in-

structions.  

Note:

  Antennas are not Listed by UL.   

GEM-Tamperkit

 - Tamper switches and screws to protect 

metal housing (see page 14).  

 
 

SPECIFICATIONS

 

  The following specifications apply to all StarLink radio mod-

els unless otherwise stated: 

 

  Electrical Ratings for 120VAC, 60Hz 

  For Models with Power Supply

 



Input Voltage:  120VAC nominal 

StarLink™ SLE  Commercial  

LTEVI & LTEAI Series  

Dual-Path Alarm Communicators  

INSTALLATION INSTRUCTIONS 

WI2327ELF  11/19 

333 Bayview Avenue, Amityville, New York 11701 

For Sales and Repairs, (800) 645-9445 

For Technical Service, (800) 645-9440 or visit us at 

http://tech.napcosecurity.com/ 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ      Symbol: NSSC 

© NAPCO 2019 

INTRODUCTION 

 The 

StarLink

 LTE Series Dual-Path Commercial / Resi-

dential Fire alarm capture radio IP communicators are fully 

supervised, wireless digital two-way subscriber units.  All 

models are compatible with most 12/24VDC alarm control 

panels (always adhere to the documentation provided by 

the control panel manufacturer).  These communicators are 

for use as the primary means of communication with the 

central station and do not have backup mode capability.  

No POTS (Telco Line) connection permitted.  

See WI2140 

for programming information.   

 

  The following models are available: 

 

SLE-LTEVI-CFBPS & SLE-LTEAI-CFBPS

:  Commercial / 

Residential Fire LTE Radio-TCP/IP Communicators in 

red metal housing with SLE-ULPS-R power supply and 

16.5V / 20VA transformer mounted inside housing 

 

SLE-LTEVI-CFB & SLE-LTEAI-CFB

:  Commercial / Resi-

dential Fire LTE Radio-TCP/IP Communicators in red 

metal housing.  Powered directly from control panel (no 

power supply, no transformer, rated nominal 12/24VDC 

input) 

 

  The following features are included with models that in-

clude a SLE-ULPS-R power supply:   

 



Power limited output to the StarLink radio PC board 12V 

input terminals 



Battery connection red and black flying leads 



Monitored battery charging and Active battery test circuits 



StarLink radio trouble input (from StarLink radio PC 

board 

PGM1 

terminal to detect StarLink radio trouble) 



Requires a sealed lead acid min 4AH / max 7AH battery 

for minimum 24-hour standby time (max charge current 

200mA). 



Trouble relay output (

C

N/O 

and 

N/C

 terminals) to 

wire to a panel zone dedicated to "Radio Trouble" (dry 

contacts).  Remove jumper "

J2

" isolate relay OUT1 

common from ground 



Green 

AC ON 

LED visible from the exterior housing 



Yellow 

TROUBLE 

LED "

D4

" on PC board.  Flashes sig-

nify: 

 

One flash: AC fail / brownout 

Two flashes: Low battery 

Three flashes: Charging circuit trouble 

Four flashes: StarLink radio trouble 

 

  The housing-mounted transformer (when provided) is 

mounted inside its own housing compartment with a re-

placeable UL Listed .5A fast blow primary fuse.  120VAC 

connections are to be made by a licensed electrician using 

suitable connectors, in accordance with N.E.C. and local 

code requirements. 

 

AGENCY LISTINGS 



UL 864 Standard For Control Units and Accessories For Fire 

Alarm Systems, 10th Edition 



UL 1610 Standard For Central-Station Burglar-Alarm Units 



UL 985 Standard For Household Fire Warning System Units 



UL 1023 Standard For Household Burglar-Alarm System Units 



UL 1076 APOU Proprietary Alarm Systems 



UL 365 APAW Police Connect 

Содержание StarLink SLE-LTEVI Series

Страница 1: ...ential Fire alarm capture radio IP communicators are fully supervised wireless digital two way subscriber units All models are compatible with most 12 24VDC alarm control panels always adhere to the d...

Страница 2: ...Smart Channel input Active high input for wiring to the control panel bell output When this input detects a pulsing temporal 3 high it sends a Fire alarm a pulsing temporal 4 CO Alarm a CO alarm is se...

Страница 3: ...or wet contacts TB22 N O OUT2 Normally open Dry contact Form C relay TB23 C OUT2 Common Dry contact Form C relay Relay rated 30V AC DC 500mA TB24 N C OUT2 Normally closed Dry contact Form C relay LED...

Страница 4: ...ded on the premises then only 4 hours of UPS backup are required JUMPER DESCRIPTIONS Jumper block labeled X5 from top to bottom as detailed in the table below Note Contact ID is always available in re...

Страница 5: ...s STEP 2 SELECT A MOUNTING LOCATION The mounting location should be indoors within the protect ed area and selected based on RF performance It is HIGHLY recommended that the installer carefully adhere...

Страница 6: ...ly trouble output relay to the two terminals of the control panel zone dedicated to the trouble With the GEMC Commercial Fire control panels use the dry contacts of the Power Supply relay by removing...

Страница 7: ...apcoNOC com to enable Tip Ring Wiring Fault Report Refer to wiring diagram Supervision Time Schedule Considerations If a status change alarm trouble etc is transmitted the radio supervision timer is r...

Страница 8: ...8 StarLink SLE Commercial LTEVI LTEAI Series Dual Path Alarm Communicators Installation Instructions This page intentionally left blank...

Страница 9: ...ition maintain a minimum 1 4 separation of all primary wiring in the transformer compartment from the yellow secondary wires of the transformer Remove shunt J2 to isolate relay OUT1 common from ground...

Страница 10: ...C 20VA transformer Optional if not used connect 10K resistor between terminals 9 and 10 IN4 StarLink BATTERY RED BLACK 8 9 10 N C COM N O J2 Note Battery leads are not power limited 10k 10k 10k TELCO...

Страница 11: ...s 1 and 2 observing polarity 10k 12V or 24V AUX PWR 10k 10k Refer to section SUPPLYING POWER DO NOT USE EOLR EOLR J2 jumper off This connection only used with Power Supply SLE ULPS R These connections...

Страница 12: ...ol Panel PC Board Refer to section SUPPLYING POWER Not required if JP2 shunt is removed and FACP monitors TELCO 2 Program only TELCO 1 supervision Note Connect IN2 to a panel output used for identifyi...

Страница 13: ...telephone connections primary and secondary for supervision and central station reporting through the StarLink SLE LTEVI FIRE radio By removing the JP2 shunt and enabling the feature Tip Ring Wiring F...

Страница 14: ...that opening the enclosure door will cause a tamper alarm Wiring a normally closed sensor loop for tamper supervision wire to a zone on the control panel GEM Tamperkit consists of Description QTY SC2...

Страница 15: ...TRF12 T123 TRANSFORMER FOR CONNECTION TO SLE CHARGER BOARD UL LISTED SURFACE OR FLUSH MOUNT OUTLET BOX AND NON SWITCHED RECEPTACLE WALL TRANSFORMER SECONDARY WIRING CONDUIT LIMITED TO 20 FEET MAXIMUM...

Страница 16: ...ay not be compromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all c...

Отзывы: