NAPCO Gemini C-Series Control Panel Installation Instructions--Volume 2
Installation Instructions, Volume 2 Page 65
NON-CP-01 OPTIONS
Non CP-01 Options/Features:
In NAPCO C-Series control panels that do not have the CP-01 label affixed, non-CP-01 functions can be programmed into the
control panel. These features and their associated address programming locations are described below:
•
Ambush Type 1
:
(a 2-digit prefix code), this type must not be used in a SIA CP-01 compliant system. Enable as follows: (a)
select "Ambush to Report Event Telco 1/Telco 3"; enter "Global Ambush Code"; and (c) enter an "Ambush CS Report Code".
Each keypad is enabled for "Ambush" individually. This Arm/Disarm Code must be entered less than 10 seconds after the
Ambush Code for an ambush report to be sent. When "ENABLE GLOBAL AMBUSH" is selected and no Ambush code has
been entered and the keypads have been selected for AMBUSH, then the AMBUSH CODE will default to "99".
Required CP-01 Options/Features:
1.
Automatic Interior Bypass / Easy Exit
.
Address 5326, Option 1 (5326 1 · · · · · · ·)*
2.
Select Burg Bell on Keyfob Arming
.
This feature must be programmed in a CP-01 installation if a GEM-KEYF is used in the system.
Address 5327, Option 7 (5327 · · · · · · 7· )*
3.
Report Cancel Window
.
Address 8168
4.
Auto-Reset
This Zone Option feature must be programmed on all Burglary zones.
Features that may NOT be programmed in CP-01 Installations:
1.
"Enable Global Ambush
" Do not program
2.
Swinger Shutdown
. Do Not Program on any zones
Required CP-01 Error Check
Note 1:
At least one
Exit / Entry zone
must be programmed for each Burg area (SIA CP-01 Specification 4.2.1).