L
NAPCO Security Systems
X
GEM-P1664 Programming Instructions
Page 53
WI1423A 1/06
KEYPAD CONFIGURATION MODE
This section will focus on configuring the GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and GEM-
RP4RFC/GEM-K4RF Keypads.
For ease of programming, it is recommended that a GEM-RP1CAe2 or a GEM-K1CA
be selected (see WI1422 for Programming Instructions using the GEM-RP1CAe2 or GEM-K1CA keypads)
.
KEYPAD INSTALLATION
Each keypad must be assigned an address number (1–7) and each requires its own configuration procedure (see
CONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS).
At least 1
keypad must be used; only 1 is required for a single-area Commercial Burglary installation.
GEM-RP2ASe2/GEM-K2AS
- are utility LCD keypads combining several preset LCD words with a limited
message line.
NOTE:
Due to space constraints, available messages are abbreviated and will scroll
automatically.
CONFIGURING THE KEYPADS
Configuring the GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and GEM-
RP4RFC/GEM-K4RF Keypads
Up to 7 GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and/or GEM-RP4RFC/GEM-K4RF keypads may
be connected to the panel (Keypads 1–7). Each must be configured for a keypad address. In addition, the keypad may
be configured to disable (a) touchpad backlight; (b) LCD backlight; and
(c) entry sounder. Keypads are configured by the proper selection of
jumpers. Refer to the label on the circuit board insulation paper for
jumper locations and a summary of settings.
KEYPAD ADDRESS
If more than one keypad is installed:
Each must be assigned a unique address (that is, no two keypads
may be numbered alike).
Keypads must be addressed consecutively (that is, missing
numbers are not permitted).
Assign the keypad address number by selecting Jumpers J1–3 in
accordance with the table at right.
TOUCHPAD BACK LIGHT
Cut Jumper A to disable touch pad backlighting to conserve 11mA standby current.
LCD BACKLIGHT
Cut Jumper B to disable LCD backlighting.
DISABLE SOUNDER
Cut Jumper C to disable the sounder. (Do not disable in UL applications).
KEYPAD
NUMBER
1
2
3
PARK
1
OFF
or
ON
OFF OFF
2
OFF
ON
OFF
STORE SPARE
3
ON
ON
OFF
JUMPER AT THIS
4
OFF OFF OFF
POSITION
5
ON
OFF
ON
6
OFF
ON
ON
7
ON
ON
ON
KEYPAD ADDRESS SETTING
Ke
yp
ad Configur
ation Mode:
Con
figuring the Ke
yp
ads