(A) 50ms Loop Response only available for zones 1-8.
(B) 2-wire Smoke Detectors only available for zones 7 & 8, and
Fire
must also be selected.
(C) If Fire Alarm Verification is selected, then Fire must also be selected.
DEFAULTS:
The zone options indicated are automatically set after exiting the Easy Menu Driven Mode.
--Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown
and
Zone Area 1
are enabled for the total number of zones entered in “
# OF ZONES IN AREA1 ENTER # ZONES
”.
--Alarm Telco 1
is enabled for the zone number(s) entered in “
REPORT ALL ZONES TO CENTRAL ZONES? Y/N
”.
--Entry/Exit 1
and
Chime
are enabled for the zone number(s) entered in “
ENTRY/EXIT ZONES ENTER ZONE #
”.
--Exit/Entry Follower
and
Interior Bypass
are enabled for the zone number(s) entered in “
INTERIOR ZONES ENTER ZONE #
”.
--Pulse Alarm Output
is enabled for the zone number(s) entered in “
FIRE ZONES ENTER ZONE #
” or “
2-WIRE FIRE ZNS ENTER ZONE #
”.
--Fire
is enabled for the zone number(s) entered in “
FIRE ZONES ENTER ZONE #
”.
--
2-Wire Smoke Detector is enabled for the zone number(s) entered in “
2-WIRE FIRE ZNS ENTER ZONE #
”.
ZONE OPTIONS - ZONES 49 TO 64 (ADDRESS 1285-1400)
Direct
A
d
dress Program Mode
ZONE OPTIONS
ZONES 61-64
LEFT DATA VALUES
ADDRESS
ZONES 57-60
RIGHT DATA VALUES
ZONES 53-56
LEFT DATA VALUES
ADDRESS
ZONES 49-52
RIGHT DATA VALUES
ZN64 ZN63 ZN62 ZN61 L ADDR R ZN60 ZN59 ZN58 ZN57 ZN56 ZN55 ZN54 ZN53 L ADDR R ZN52 ZN51 ZN50 ZN49
Priority
8
4
2
1
1349
8
4
2
1
8
4
2
1
1285
8
4
2
1
Priority with Bypass
8
4
2
1
1350
8
4
2
1
8
4
2
1
1286
8
4
2
1
Auto-Bypass
8
4
2
1
1351
8
4
2
1
8
4
2
1
1287
8
4
2
1
Selective Bypass
8
4
2
1
1352
8
4
2
1
8
4
2
1
1288
8
4
2
1
Keyswitch Arming
8
4
2
1
1353
8
4
2
1
8
4
2
1
1289
8
4
2
1
Auto-Bypass Re-entry
8
4
2
1
1354
8
4
2
1
8
4
2
1
1290
8
4
2
1
Pre-Alarm Warning
8
4
2
1
1355
8
4
2
1
8
4
2
1
1291
8
4
2
1
Never Arm
8
4
2
1
1356
8
4
2
1
8
4
2
1
1292
8
4
2
1
24-Hour Zone
8
4
2
1
1357
8
4
2
1
8
4
2
1
1293
8
4
2
1
Alarm Output
8
4
2
1
1358
8
4
2
1
8
4
2
1
1294
8
4
2
1
Pulsed Alarm Output
8
4
2
1
1359
8
4
2
1
8
4
2
1
1295
8
4
2
1
PGM1 Output
8
4
2
1
1360
8
4
2
1
8
4
2
1
1296
8
4
2
1
PGM2 Output
8
4
2
1
1361
8
4
2
1
8
4
2
1
1297
8
4
2
1
Entry/Exit 1
8
4
2
1
1362
8
4
2
1
8
4
2
1
1298
8
4
2
1
Entry/Exit 2
8
4
2
1
1363
8
4
2
1
8
4
2
1
1299
8
4
2
1
Exit/Entry Follower
8
4
2
1
1364
8
4
2
1
8
4
2
1
1300
8
4
2
1
Auto Reset
8
4
2
1
1365
8
4
2
1
8
4
2
1
1301
8
4
2
1
Swinger Shutdown
8
4
2
1
1366
8
4
2
1
8
4
2
1
1302
8
4
2
1
Chime
8
4
2
1
1367
8
4
2
1
8
4
2
1
1303
8
4
2
1
Abort Delay
8
4
2
1
1368
8
4
2
1
8
4
2
1
1304
8
4
2
1
Power-up Delay
8
4
2
1
1369
8
4
2
1
8
4
2
1
1305
8
4
2
1
Day Zone Open
8
4
2
1
1370
8
4
2
1
8
4
2
1
1306
8
4
2
1
Day Zone Short
8
4
2
1
1371
8
4
2
1
8
4
2
1
1307
8
4
2
1
Alarm on Day Zone
8
4
2
1
1372
8
4
2
1
8
4
2
1
1308
8
4
2
1
Alarm Telco 1
8
4
2
1
1373
8
4
2
1
8
4
2
1
1309
8
4
2
1
Alarm Restore 1
8
4
2
1
1374
8
4
2
1
8
4
2
1
1310
8
4
2
1
Trouble Telco 1
8
4
2
1
1375
8
4
2
1
8
4
2
1
1311
8
4
2
1
Trouble Restore 1
8
4
2
1
1376
8
4
2
1
8
4
2
1
1312
8
4
2
1
Alarm Telco 3
8
4
2
1
1377
8
4
2
1
8
4
2
1
1313
8
4
2
1
Alarm Restore 3
8
4
2
1
1378
8
4
2
1
8
4
2
1
1314
8
4
2
1
Trouble Telco 3
8
4
2
1
1379
8
4
2
1
8
4
2
1
1315
8
4
2
1
Trouble Restore 3
8
4
2
1
1380
8
4
2
1
8
4
2
1
1316
8
4
2
1
No EOL Resistor
8
4
2
1
1381
8
4
2
1
8
4
2
1
1317
8
4
2
1
Trouble on Open
8
4
2
1
1382
8
4
2
1
8
4
2
1
1318
8
4
2
1
Trouble on Short
8
4
2
1
1383
8
4
2
1
8
4
2
1
1319
8
4
2
1
Zone Area 1
8
4
2
1
1384
8
4
2
1
8
4
2
1
1320
8
4
2
1
Zone Area 2
8
4
2
1
1385
8
4
2
1
8
4
2
1
1321
8
4
2
1
Interior (Stay) Bypass
8
4
2
1
1388
8
4
2
1
8
4
2
1
1324
8
4
2
1
Keypad Sounder on Alarm
8
4
2
1
1389
8
4
2
1
8
4
2
1
1325
8
4
2
1
Fire (C)
8
4
2
1
1391
8
4
2
1
8
4
2
1
1327
8
4
2
1
Fire Alarm Verification
(C)
8
4
2
1
1392
8
4
2
1
8
4
2
1
1328
8
4
2
1
Zone ANDing Group 1
8
4
2
1
1394
8
4
2
1
8
4
2
1
1330
8
4
2
1
Zone ANDing Group 2
8
4
2
1
1395
8
4
2
1
8
4
2
1
1331
8
4
2
1
Zone ANDing Group 3
8
4
2
1
1396
8
4
2
1
8
4
2
1
1332
8
4
2
1
Zone ANDing Group 4
8
4
2
1
1397
8
4
2
1
8
4
2
1
1333
8
4
2
1
Sensor Watch
8
4
2
1
1398
8
4
2
1
8
4
2
1
1334
8
4
2
1
RESERVED
8
4
2
1
1399
8
4
2
1
8
4
2
1
1335
8
4
2
1
Chime 2
8
4
2
1
1400
8
4
2
1
8
4
2
1
1336
8
4
2
1
When the Easy Program Menu is used, these features are enabled by default.
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
Zone Area 3
8
4
2
1
1386
8
4
2
1
8
4
2
1
1322
8
4
2
1
Zone Area 4
8
4
2
1
1387
8
4
2
1
8
4
2
1
1323
8
4
2
1
Step 1
Step 4 Step 4
Step 4 Step 4
Step 2
Step 2
Step 2
Step 2
See Steps listed at
bottom of page 44