GENERAL DESCRIPTION  

The GEM-PIR is an advanced PIR sensor designed for use with 
Napco's GEM-Series wireless receivers.  The unit is powered by 
two supplied 3-volt lithium batteries (estimated battery life 3 
years).  When battery voltage drops below normal, a low-battery 
report will be sent to the receiver (replace with Duracell DL123A, 
Varta/Power-One CR123A or Panasonic CR123A only).  Coding 
switches are not used in the GEM-PIR.  Each transmitter has a 
unique factory-programmed RF ID code (printed on the unit) that 
distinguishes itself to the receiver.  (

Note:

  See control-panel in-

structions for entering this six digit hexadecimal code and check-
sum digit into the panel; be sure to enter all numbers and/or let-
ters, including leading zeros, if any). 
 

SPECIFICATIONS 
PIR Coverage (l x w):

  50' x 50' (15.2m x 15.2m) at 20°C (68°F), 

typical.   

Operating Temperature: 

 0° to +50°C (32° to 122°F) 

Mounting:

  Wall or corner, 10' (3m) max.   

Dimensions:

  4.5'' x 2.5'' x 1.7'' (11.4cm x 6.4cm x 4.3cm) 

(HxWxD)  

Shipping Weight:

  6.4oz (181gm) 

 

STANDARD LENS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FEATURES 

Signal Selective Processing for reliable operation 

Unique circuit design protects against false alarms due to 
radio-frequency interference 

Vertical and horizontal aiming capabilities 

Dual-element sensor 

Lens Bank of optional accessory lenses 

Large lens area assures high sensitivity 

Small size with ample wiring space 

Corner mountable 

Built-in Tamper microswitch 

 

REPLACING THE LENS 

The lens is ''sandwiched'' between the front case and a Lens 
Support insert, which also serves to hold the LED jewel in place.  
To install one of the accessory lenses, proceed as follows.   

WI749F 

 

07/13 

1.  To open the case, insert a small screwdriver in the slot at 

the bottom and push up slightly.  Remove the front cover.   

2.  Push up on the lower edge of the 

Lens Support until it is clear of its 
retainers, then pull out the sup-
port from the bottom.  Be careful 
not to dislodge the LED jewel.  
Note: If the LED jewel pops out, 
reinsert it with the small index 
key positioned at the top.   

3.  Slide out the lens and install the 

replacement.   

4.  Replace the Lens Support: Slip 

the Lens Support under the top guides with its two tabs 
straddling the LED jewel, then push in at the bottom until 
the Lens Support snaps into place.  Removing Lens Sup-
port. 

 

INSTALLATION 

An assortment of ''push-thru'' holes is provided in the rear case 
for wall or corner mounting.  Install the two lithium batteries as 
shown in the illustration below.  Loosen the Height Lock Screw 
and set the board's height scale to the mounted height of the 
unit.  Retighten the screw.  To reduce range if necessary, set 
height scale at a higher number than actual mounting height of 
unit.  Do not point the unit at sources of heat, such as radiators, 
space heaters, etc.  

Note: 

In UL burglary installations, the bur-

glary output must be programmed for all protective devices. 
 

WALK TESTING 

The LED will light in the Walk-Test Mode only.  Allow at least 3 
minutes for the unit to settle.  Press the Walk-Test Button to ac-
cess the Walk-Test Mode for 5 minutes.   
Walk out to the maximum range and walk across the field of 
coverage.  The LED will light whenever motion is detected.  
Check for environmental disturbances with all disruptive devices 
(heaters, air conditioners) on and no human activity within the 
coverage area.  Adjust beams laterally by removing the Lens 
Support (see REPLACING THE LENS) and sliding the lens 
slightly left or right.  To block a problem zone, apply a piece of 
lens foil (supplied) to the inside segment of the lens represent-
ing that zone. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SETTING THE OPERATING MODE 

The GEM-PIR comes set for operation in the Signal Selective 
Processing (SSP) Mode.  To change to the fixed 2-pulse bipolar 
mode for use with the Long-Range Lens* (LENS840), Barrier 
Lens* (LENS818) or other lens with a limited number of beams, 
remove the Response-Mode Jumper, J1. 

333 Bayview Avenue 

Amityville, New York 11701 

For Sales and Repairs, (800) 645-9445 
For Technical Service,  (800) 645-9440 

Publicly traded on NASDAQ     Symbol: NSSC 

© NAPCO 2013 