NAPCO Security Systems
LIBRA LIB-P432EX Series Programming Instructions
Page 45
ZONE OPTIONS - ZONES 1 TO 16 (ADDRESS 0900-1016)
ZONE OPTIONS
ZONES 13-16
LEFT DATA VALUES
(CIRCLE
)
ADDRESS
ZONES 9-12
RIGHT DATA VALUES
(CIRCLE
)
ZONES 5-8
LEFT DATA VALUES
(CIRCLE
)
ADDRESS
ZONES 1-4
RIGHT DATA VALUES
(CIRCLE
)
ZN16 ZN15 ZN14 ZN13 L ADDR R ZN12 ZN11 ZN10 ZN9 ZN8 ZN7 ZN6 ZN5
L ADDR R ZN4 ZN3 ZN2 ZN1
§
50ms Loop Response
8
4
2
1
0964
8
4
2
1
8
4
2
1
0900
8
4
2
1
Priority
8
4
2
1
0965
8
4
2
1
8
4
2
1
0901
8
4
2
1
Priority with Bypass
8
4
2
1
0966
8
4
2
1
8
4
2
1
0902
8
4
2
1
Auto-Bypass
8
4
2
1
0967
8
4
2
1
8
4
2
1
0903
8
4
2
1
Selective Bypass
8
4
2
1
0968
8
4
2
1
8
4
2
1
0904
8
4
2
1
Keyswitch Arming
8
4
2
1
0969
8
4
2
1
8
4
2
1
0905
8
4
2
1
Auto-Bypass Re-entry
8
4
2
1
0970
8
4
2
1
8
4
2
1
0906
8
4
2
1
Pre-Alarm Warning
8
4
2
1
0971
8
4
2
1
8
4
2
1
0907
8
4
2
1
Never Arm
8
4
2
1
0972
8
4
2
1
8
4
2
1
0908
8
4
2
1
24-Hour Zone
8
4
2
1
0973
8
4
2
1
8
4
2
1
0909
8
4
2
1
Alarm Output
8
4
2
1
0974
8
4
2
1
8
4
2
1
0910
8
4
2
1
Pulsed Alarm Output
8
4
2
1
0975
8
4
2
1
8
4
2
1
0911
8
4
2
1
PGM1 Output
8
4
2
1
0976
8
4
2
1
8
4
2
1
0912
8
4
2
1
PGM2 Output
8
4
2
1
0977
8
4
2
1
8
4
2
1
0913
8
4
2
1
Entry/Exit 1
8
4
2
1
0978
8
4
2
1
8
4
2
1
0914
8
4
2
1
Entry/Exit 2
8
4
2
1
0979
8
4
2
1
8
4
2
1
0915
8
4
2
1
Exit/Entry Follower
8
4
2
1
0980
8
4
2
1
8
4
2
1
0916
8
4
2
1
Auto Reset
8
4
2
1
0981
8
4
2
1
8
4
2
1
0917
8
4
2
1
Swinger Shutdown
8
4
2
1
0982
8
4
2
1
8
4
2
1
0918
8
4
2
1
Chime
8
4
2
1
0983
8
4
2
1
8
4
2
1
0919
8
4
2
1
Abort Delay
8
4
2
1
0984
8
4
2
1
8
4
2
1
0920
8
4
2
1
Power-up Delay
8
4
2
1
0985
8
4
2
1
8
4
2
1
0921
8
4
2
1
Day Zone Open
8
4
2
1
0986
8
4
2
1
8
4
2
1
0922
8
4
2
1
Day Zone Short
8
4
2
1
0987
8
4
2
1
8
4
2
1
0923
8
4
2
1
Alarm on Day Zone
8
4
2
1
0988
8
4
2
1
8
4
2
1
0924
8
4
2
1
Alarm Telco 1
8
4
2
1
0989
8
4
2
1
8
4
2
1
0925
8
4
2
1
Alarm Restore 1
8
4
2
1
0990
8
4
2
1
8
4
2
1
0926
8
4
2
1
Trouble Telco 1
8
4
2
1
0991
8
4
2
1
8
4
2
1
0927
8
4
2
1
Trouble Restore 1
8
4
2
1
0992
8
4
2
1
8
4
2
1
0928
8
4
2
1
Alarm Telco 3
8
4
2
1
0993
8
4
2
1
8
4
2
1
0929
8
4
2
1
Alarm Restore 3
8
4
2
1
0994
8
4
2
1
8
4
2
1
0930
8
4
2
1
Trouble Telco 3
8
4
2
1
0995
8
4
2
1
8
4
2
1
0931
8
4
2
1
Trouble Restore 3
8
4
2
1
0996
8
4
2
1
8
4
2
1
0932
8
4
2
1
No EOL Resistor
8
4
2
1
0997
8
4
2
1
8
4
2
1
0933
8
4
2
1
Trouble on Open
8
4
2
1
0998
8
4
2
1
8
4
2
1
0934
8
4
2
1
Trouble on Short
8
4
2
1
0999
8
4
2
1
8
4
2
1
0935
8
4
2
1
Zone Area 1
8
4
2
1
1000
8
4
2
1
8
4
2
1
0936
8
4
2
1
Zone Area 2
8
4
2
1
1001
8
4
2
1
8
4
2
1
0937
8
4
2
1
Interior (Stay) Bypass
8
4
2
1
1004
8
4
2
1
8
4
2
1
0940
8
4
2
1
Keypad Sounder on Alarm
8
4
2
1
1005
8
4
2
1
8
4
2
1
0941
8
4
2
1
2-Wire Smoke Detectors
8
4
2
1
(•) 1006 (•)
8
4
2
1
8 4
2
1
0942 (•)
8
4
2
1
Fire
8
4
2
1
1007
8
4
2
1
8
4
2
1
0943
8
4
2
1
Fire Alarm Verification
8
4
2
1
1008
8
4
2
1
8
4
2
1
0944
8
4
2
1
RESERVED
8
4
2
1
(•) 1009 (•)
8
4
2
1
8
4
2
1
(•) 0945 (•)
8
4
2
1
Zone ANDing Group 1
8
4
2
1
1010
8
4
2
1
8
4
2
1
0946
8
4
2
1
Zone ANDing Group 2
8
4
2
1
1011
8
4
2
1
8
4
2
1
0947
8
4
2
1
Zone ANDing Group 3
8
4
2
1
1012
8
4
2
1
8
4
2
1
0948
8
4
2
1
Zone ANDing Group 4
8
4
2
1
1013
8
4
2
1
8
4
2
1
0949
8
4
2
1
Sensor Watch
8
4
2
1
1014
8
4
2
1
8
4
2
1
0950
8
4
2
1
RESERVED
8
4
2
1
1015
8
4
2
1
8
4
2
1
0951
8
4
2
1
Chime 2
8
4
2
1
1016
8
4
2
1
8
4
2
1
0952
8
4
2
1
§
50ms Loop Response only available for zones 1-4. If Zone Doubling is enabled, Zones 9-12 will follow the loop response programming for Zones 1-4.
When the Easy Program Menu is used, these features are enabled by default.
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
NOTE:
(Address Location 0942 can only be programmed as "blank (•) blank (•)", "4 blank (•)", "8 blank (•)" or "C blank (•)".
Zone Area 3
8
4
2
1
1002
8
4
2
1
8
4
2
1
0938
8
4
2
1
Zone Area 4
8
4
2
1
1003
8
4
2
1
8
4
2
1
0939
8
4
2
1
1.
Select
the desired zone option.
ZONE OPTIONS
§
50ms Loop Response
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
3.
Search table
below for data entry.
4.
Enter data
in address locations (left and right
digits). Press [Enter] or [ON/OFF] to save.
L
ADDR
R
blank (•) 0490
1
ADDRESS LOCATION
NOTE:
Dark shaded boxes = option not available.
See Direct Address Programming Example page 22.
4
8
2 1
DIGIT VALUE DATA ENTRY
Blank (
.
)
4
8
2 1
1
4
8
2 1
2
8
1
2
4
3
4
8
2 1
4
5
4
8
2 1
4
8
2 1
6
4
8
2 1
7
4 2 1
DIGIT VALUE DATA ENTRY
8
4 2 1
9
4 2 1
0
1
2
4
B
4 2 1
C
D
4 2 1
4 2 1
E
4 2 1
F
8
8
8
8
8
8
8
8
Step 1
Step 4
Step 4
Step 4
Step 4
Step 2
Step 2
Step 2
Step 2
See steps listed at
bottom of page
2.
Enable
desired options for each zone
by drawing a circle around its
corresponding binary data value.
NOTE:
No circle = feature disabled.
s
Содержание GEM-DXK2
Страница 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM ...
Страница 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM ...
Страница 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM ...
Страница 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES ...