NAPCO Security Systems
LIBRA LIB-P432EX Series Programming Instructions
Page 33
ZONE ANDING TIME WINDOW (ADDRESS 2061)
ZONE ANDING TIME WINDOW
:
With Zone ANDing enabled, the system will go into alarm
only if any two zones in a group are tripped within a specified period of time. With this address, this
time window is adjustable between 1 and 255 seconds. The factory default is 60 seconds.
Note:
If the address is programmed to 0, the panel defaults to 60 seconds.
KEYPAD UNBLANKING TIME WINDOW (ADDRESS 2060)
KEYPAD BLANKING TIME WINDOW
:
If a keypad (RP1, RP2) is Blanked/System
event mode, enabling the keypad to normal requires a Set/Unset code + Enter (level2/3/4)
to come alive. The keypad will stay alive (Normal) for 128 seconds (default) or for a time in
a programmable in an EEProm location in seconds. This location, 2060, contains a 3 digit
decimal and is called Keypad Un-blanking Period. During exit/entry delay all keypads will
always come ALIVE (Normal).
See "Zone ANDing Time Window" (above) for programming procedure.
CLOCK ADJUSTMENTS (ADDRESS 2281)
1. Select time window (0-255 sec.) from the table shown at left.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20 sec.
B. Divide it by 16
4. Press
u
to save.
EXIT/ENTRY DELAYS:
Apply only to zones programmed with the following options “Exit/Entry 1, Exit/Entry 2, Exit/
Entry Follower”.
NOTE:
Sensor Watch Time Options are similar to above table, except in hours. Either use the
tables provided or calculate your own timeout using the steps indicated.
WARNING: Timers have
uncertainty of +/-1sec, so a "time" of 1 second may actually timeout IMMEDIATELY.
1 Quotient Left Digit
16 20
16
4 Remainder Right Digit
DELAY/
LEFT
RIGHT TIMEOUT
blank (•) blank (•)
0 sec.
blank (•)
F
15 sec.
1
E
30 sec.
2
D
45 sec.
3
C
60 sec.
5
0
90 sec.
7
8
120 sec.
F
F
255 min.
DATA ENTRIES
ADDRESS 2061
LEFT RIGHT
[Default = 3 C]
Zone
ANDing
Time
Window
(seconds)
ADDRESS 2060
LEFT RIGHT
[Default = 8 blank (
•
)]
Keypad
Unblanking
Time
Window
(seconds)
*[Default = AC Source used]
**[Default = 60Hz]
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2281
CLOCK ADJUSTMENTS:
1. Select the desired option by circling
the data values for each digit (left and right).
2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23).
3. Enter in address location (left and right digits).
NOTE:
Dark shaded data value box shows option not available. Press
u
to save.
CLOCK ADJUSTMENTS
LEFT DATA
VALUES
(CIRCLE
)
RESERVED
1
RESERVED
2
RESERVED
4
RESERVED
8
RIGHT DATA
VALUES
(CIRCLE
)
CLOCK ADJUSTMENTS
1
Enable Daylight Saving Time
2
Clock Source (Internal Panel )*
4
Line Frequency--Enable 50Hz **
8
RESERVED
Содержание GEM-DXK2
Страница 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM ...
Страница 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM ...
Страница 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM ...
Страница 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES ...