1
R
Using your
NAPCO
FREEDOM
F-TPBR Touchpad
Home Security System
© NAPCO 2005
PATENTED OI308 10/05
NIGHT
DISARM/
SILENCE
BYPASS
STAY
F-TPBR_OI308.06_USER_anc...
page 1
Friday, October 28, 2005 15:14
Composite
Страница 1: ...1 R Using your NAPCO FREEDOM F TPBR Touchpad Home Security System NAPCO 2005 PATENTED OI308 10 05 NIGHT DISARM SILENCE BYPASS STAY F TPBR_OI308 06_USER_anc page 1 Friday October 28 2005 15 14 Composite ...
Страница 2: ...ighest industry stan dards Please test your system at least once a week as described below INTRODUCTION 1 Test your siren and central station communicator Hold Down the BYPASS button for 4 seconds until the F TPBR Touchpad beeps The system will generate a test report to central station and two momentary chirps of the siren If the siren does not sound or sounds week call for service If the system i...
Страница 3: ...OR CODES 14 ZONE LIST 16 FCC PART 68 STATEMENT 17 LIMITATIONS OF THIS ALARM SYSTEM 18 LIMITED WARRANTY 20 FCC PART 15 STATEMENT 22 ALARM TIME OUT _________ Minutes FOR SERVICE CALL _____________________ TO CANCEL AN ALARM REPORT CALL ____________________ IF THE ALARM IS SOUNDING To silence an alarm in sert your F IFOB key into the slot on the F TPBR Touchpad and remove when alarm has si lenced Pro...
Страница 4: ... with all interior protection off all perimeter protection on This allows free movement inside the interior of the premises The red ARMED light ON indicates that the system is armed BLINKING with the siren sounding indicates that the system is in alarm BLINKING with no siren indicates Alarm Memory the alarm has been silenced or timed out To determine the zone in alarm count the number of flashes a...
Страница 5: ...m includes fire protection BYPASS Button This button has multiple functions depending on the state of the panel BYPASS If you are attempting to arm the system with open zones that cannot be immediately repaired press BYPASS to tempo rarily remove these zones from the system The F TPBR Touchpad will beep and trouble TBL will light steady Press STAY or NIGHT to arm the system as usual see page 6 TES...
Страница 6: ... removed from the system or bypassed using the fol lowing procedure 1 Press the BYPASS button The F TPBR Touchpad will beep and the yellow Trouble indicator will light ON STEADY 2 Press either the STAY or NIGHT button Warning Bypassed zones are unprotected If a faulted zone cannot be secured have the system checked as soon as possible TBL F TPBR_OI308 06_USER_anc page 6 Friday October 28 2005 15 1...
Страница 7: ...door or window etc If you cannot immediately secure the zone it may be bypassed see page 6 If the green READY light is OFF the deadbolt is not locked The Touchpad deadbolt must be locked before the system can be armed Go to the Touchpad and lock the deadbolt 2 Press the STAY button The STAY and ARMED indicator will light steady indicating the system is armed in the Stay mode To Arm in Night Mode f...
Страница 8: ...oor or window etc If you cannot immediately secure the zone it may be bypassed see page 6 If the green READY light is OFF the deadbolt is not locked The Touchpad deadbolt must be locked before the system can be armed Go to the Touchpad and lock the deadbolt 2 Press the NIGHT button The ARMED indicator will light and STAY will begin to flash indicating the system is armed in the Night mode To Arm i...
Страница 9: ...e central station of a police emergency Police Emergency programmed YES NO Fire Emergency Hold down the Fire button to alert the central station of a fire emergency Fire Emergency programmed YES NO Auxiliary Emergency Hold down this button to alert the central station of an auxiliary emergency Auxiliary Emergency programmed YES NO Auxiliary Emergency _______________________________________ Emergen...
Страница 10: ...mode interior fully protected pressing the DISARM SILENCE button will not only fail to disarm the system but pressing ANY button when armed Away will instantly generate an alarm The system may also be disarmed at any time with the F IFOB To disarm the system insert your F IFOB key into the IFOB slot on the F TP Touchpad or F TPBR Touchpad and remove when the system is disarmed F TPBR_OI308 06_USER...
Страница 11: ...ou are away When you unlock the deadbolt to enter the Touchpad sounders will activate and the red ARMED light will be flashing to warn you that an alarm had occurred while you were away Proceed with caution If you suspect that an intruder may still be on the premises leave immediately and call authorities from a neighbor s phone To disarm the system you must insert your F IFOB key into the F IFOB ...
Страница 12: ...ted by smoke detectors the light on the active detector will be lit Once it is determined which smoke detector is in alarm press DISARM SILENCE to reset the smoke detector 4 If the Fire Zone has reset properly the FIRE light should go out in approximately 30 seconds If it does not go out press DISARM SILENCE again in a few minutes If it still does not go out call for service Fire Zone Trouble The ...
Страница 13: ... sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not stop to pack 3 Test the door If it is hot use your alternate route through the window If the door is cool brace your shoulder against it and open it cautiously Be ready to slam the door if smoke or heat rushes in Crawl through smoke holding your breath ...
Страница 14: ...Flashes Touchpad beeps READY Flashes Trouble Condition Action STEADY NONE Zones Bypassed This is a reminder that zones have been bypassed by pressing BYPASS If it is necessary to bypass any inoperative zones it is important to have the zones re paired as soon as possible 1 NONE AC Power Failure This trouble will occur if AC power is not present Make sure the system trans former is plugged into its...
Страница 15: ...nd GEM GB glass break detector is the Duracell DL123A 3 Volt Lithium 2 required for the GEM PIR and GEM GB The GEM DT Dual Technology Sensor requires 4 C cell Alkaline batter ies Warning Replace batteries only with the same type as specified above Use of another battery may present a risk of fire or explosion Do not recharge or disassemble battery or dispose of in fire 4 1 8 Wireless Transmitter S...
Страница 16: ... refer to the list below to see which zone is open and secure it close the door or window etc If an alarm has occurred count the number of ARMED light flashes and refer to the list below to see which zone caused the alarm ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 ZONE LIST F TPBR_OI308 06_USER_anc page 16 Friday October 28 2005 15 14 Composite ...
Страница 17: ...tify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make the necessary modifi cations in o...
Страница 18: ...assive Infrared Detectors do not provide volumetric area protection They do create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by those beams They cannot detect motion or intrusion that takes place behind walls ceilings floors closed doors glass partitions glass doors or windows Mechanical tampering mask ing painting or spraying of any material on ...
Страница 19: ... conditions Lon gevity of batteries may be as much as 4 to 7 years depending on the environment usage and the specific wireless device being used External factors such as humidity high or low temperatures as well as large swings in temperature may all reduce the ac tual battery life in a given installation This wireless system however can identify a true low battery situation thus allowing time to...
Страница 20: ...ed to any implied warranty of merchantability must be brought within the six months following the end of the warranty period IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT In case of defect contact the security professional...
Страница 21: ...e product or system will in all cases provide adequate warning or protection A properly installed and maintained alarm may only reduce risk of burglary robbery fire or otherwise but it is not insurance or a guarantee that these events will not occur CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING ...
Страница 22: ...e separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help You may also find the helpful the following booklet prepared by the FCC How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Governm...
Страница 23: ...23 NOTES F TPBR_OI308 06_USER_anc page 23 Friday October 28 2005 15 14 Composite ...
Страница 24: ...ue Amityville New York 11701 For Sales and Repairs 800 645 9445 For Technical Service 800 645 9440 Publicly traded on NASDAQ Symbol NSSC R NAPCO 2005 F TPBR_OI308 06_USER_anc page 24 Friday October 28 2005 15 14 Composite ...