background image

 

ADVANCED ADAPTIVE PIR/MICROWAVE 

TECHNOLOGY SENSORS 

 

GEMC-BSLC-DT-L "DUAL TECH" 

 

INSTALLATION INSTRUCTIONS 

GENERAL DESCRIPTION 

 

SPECIFICATIONS

 

General Coverage 

with standard wide-angle lens, meas-

ured indoors at 68°F (20°C), typical:  50 feet long x 40 feet 
wide; plus "Look-down" zone. 

Operating Temperature:  

14° to 122°F (-10° to +49°C)  

Mounting:  

Wall or corner, 6 - 9.8 feet (2 - 3m) maximum 

Microwave Frequency:  

10.525GHz ±25MHz  

Dimensions

 (HxWxD):  4.6 x 2.5 x 2.5"  (11.7 x 6.35 x 

6.35cm) 

Shipping Weight: 

 .3

 

lb (4.8oz, 136g)  

 

Electrical Ratings 
Input Power:

  13.6-16.3VDC supplied by model GEMC-

BSLC, 4mA. 

Maximum Wiring Length:

  2000' (#16 AWG).  Refer to 

GEMC-BSLC documentation for complete wiring infor-
mation.  Unit shall be connected to model GEMC-BSLC 
which is employed in the GEMC C-Series control panel 
which is provided with a minimum of 4 hours standby on 
battery power. 

 

FEATURES 



Microprocessor signal processing 



Utilizes analog to digital signal conversion 



System diagnostic electronics 



Watchdog microprocessor supervision 



Dual-element PIR sensor 



High-efficiency, dirt-resistant grooves-in lens  



"Look-down" zone 



Extensive RFI and EMI filtering ensure optimum immunity 
to false alarms 



Large lens area assures high PIR sensitivity 



Selectable microwave/PIR LED indication visible from 
virtually any angle, extinguishable after testing. 



Small size; modern, unobtrusive design 



Silent operation 



Bracket-free corner or wall mountable 



Universal Swivel Bracket Kit available (not evaluated by 
UL) 

 

ORDERING INFORMATION 

 SVLBKT  Swivel 

Bracket 

Kit 

 

BASIC OPERATION 

  This unit is a combination passive-infrared (PIR) sensor and 

microwave sensor, both contained in a single package.  The 
unit will go into alarm when both sensors detect intrusion at 
the same time.  The PIR section operates by detecting a 
rapid change in temperature when an intruder crosses a 

protected area.  When a beam experiences a change in 
heat (projected back through the lens), a pulse is generated 
by the sensor element.  The microwave transmitter sends 
out short bursts of RF energy, and the receiver detects 
changes in the returned signal caused by motion within its 
coverage area. 

  The microwave section is unaffected by visible light, air 

drafts, or temperature changes (as from space heaters or air 
conditioners, for example), but is sensitive to motion.  Strong 
vibrations can be troublesome.  Microwave signals may 
pass through non-metallic walls and windows.  Infrared is 
virtually unaffected by vibration, and will not penetrate walls 
or windows. 

  Thus the two technologies complement each other, and it is 

the combination of the two that provides an inherent immun-
ity to false alarms.  Dual technology is ideal for use in hostile 
environments.  Since both must trip to cause an alarm, in-
stallation is easier and requires less discipline. 

 

DETECTION PATTERNS 

  Figure 1 illustrates maximum PIR and microwave detection 

patterns superimposed on each other. 

Fig. 1.

  GEMC-BSLC-DT-L wide-angle lens patterns showing maximum 

recommended coverage: 

(a) top view; 
(b) side view for 6' mounting height. 

50' 

40' 

85° 

(a) 

PIR 

MW 

6' 

PIR 

MW 

                                                                               

10'

                                                  

20'

                                                   

30'

                                                 

40'

                                                 

50 

(b) 

WI2071A\1  06/14 

333 Bayview Avenue 

Amityville, New York 11701 

For Sales and Repairs, (800) 645-9445 

For Technical Service, (800) 645-9440 or visit us at 

http://tech.napcosecurity.com/ 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ      Symbol: NSSC 