background image

DTW14FL 

Rev. 12/11/14

DTW14FL

1/4" Torque Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.44 ft.-lbs.-8.85 ft.-lbs.
Accuracy (*1)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(CCW ±3%) (CW ±4%) 
Data Memory Values  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   50
Number of Presets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Peak Hold/Track
Unit Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ft-lb, in-lb, N-m, & kg-cm
Head Type  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fixed Head
Gear teeth  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Audible Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes
Buttons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
LED Indicator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 LED's
Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 AAA
Battery Life-Continuous Operation (*2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Hrs
Battery Life-Standby (*2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Year
Operating Temperature  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14ºF ~ 140ºF
Storage Temperature  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -4ºF ~ 158ºF
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Up to 90% non-condensing

SPECIFICATIONS

AlwAys reAd  
instructions 
before using 
tools 

AlwAys weAr  
sAfety 
goggles

not 
wAterproof

DTW14FL

1/4" Dr. Digital Torque Wrench

WARNING

Содержание Carlyle DTW14FL

Страница 1: ...Type Fixed Head Gear teeth 60 Audible Alarm Yes Buttons 5 LED Indicator 2 LED s Batteries 1 AAA Battery Life Continuous Operation 2 12 Hrs Battery Life Standby 2 1 Year Operating Temperature 14 F 140...

Страница 2: ...ic rights You may also have other rights which vary from state to state The foregoing obligation is Carlyle Professional Hand Tools sole liability under this or any implied warranty and under no circu...

Страница 3: ...ator M1 M9 No other internal parts are available due to the sensitivity of this professional model Please utilize the repair facility listed under the warranty statement for all repairs in and out of...

Страница 4: ...14 RePlacing the Head Kit cont DISASSEMBLY Step 1 Take off the cover and spring by tip end handle See Fig 1 Step 2 Use the tweezers to take out the square drive pawl and spring cap by the sequence Se...

Страница 5: ...cont Step 3 Pick out the stator using side cutter Then the switch spring and steel ball can be removed simultaneously by tweezers See Fig 3 RE ASSEMBLY Step 1 Use tweezers to put spring and steel ball...

Страница 6: ...switch by finger and put the stator in at the same time Use flat head screwdriver to press them to its position See Fig 5 Step 3 Put in spring spring cap and pawl Hold it by hand to prevent the pawl...

Страница 7: ...or 5 minutes to save power Press to wake from Sleep mode SET UP RESETTING THE WRENCH If the wrench does not function normally 1 Power On Clear 2 Unit Setting 3 Memory Stores up to 9 values 4 Up Down 1...

Страница 8: ...ial torque will be shown in the display Some or all the lights will illuminate and the wrench will sound a continuous alarm tone To clear the display and stop the alarm press the button SELECTING UNIT...

Страница 9: ...e values Torque Wrench comes with 9 Preset values pre installed at the factory SELECTING Track and PEAK MODES At start up either a P or T will show in the lower right hand corner of the display depend...

Страница 10: ...values have been stored NOTE A maximum of 50 values can be stored in the Peak Hold memory The word FULL appears in the display when an attempt is made to store more than the allotted maximum Track MOD...

Страница 11: ...the value that was in location 4 moves down one slot and becomes value 3 The value in location 5 moves to 4 etc Deleting a Peak Hold Value Deleting all Peak Hold Values 1 Repeat steps 1 3 above 2 Pre...

Страница 12: ...DTW14FL 12 Rev 12 11 14 NOTES Memory Prest Location Newton meters N m inch pounds in lb foot pounds ft lb kilogram centimeters kg cm angle degree 1 2 3 4 5 6 7 8 9...

Страница 13: ...de engranaje 60 Alarma audible S Botones de control 5 Indicador LED 12 l mparas LED Bater as 1 AAA Operaci n de vida continua de la bater a 2 12 horas Vida de la bater a de reserva 2 1 a o Temperatur...

Страница 14: ...o exclusi n anterior puede no ser aplicable para usted Para servicio de garant a y servicios de recalibrado certificaci n comun quese con Torque Wrench Repair Facility 315 Hawkins Rd Travelers Rest SC...

Страница 15: ...moria M1 M9 LAS PARTES DE REPUESTO DISPONIBLES COMO RSDTW14FLBC Tapa de bater a RSDTW14FLCS Estuche moldeadp por soplado RSDTW14FLHRP Equipo de reparaci n de cabeza para DTW14FL Ninguna otra parte est...

Страница 16: ...DEL JUEGO DE CABEZA DESENSAMBLE Paso 1 Quite la tapa y resorte por el mango de extremo de punta Ver la fig 1 Paso 2 Use las pinzas para extraer el encaje cuadrado trinquete tapa de resorte seg n la s...

Страница 17: ...estator usando el cortador lateral Luego se pueden extraer simult neamente el interruptor resorte y bola de acero con las pinzas Ver la fig 3 REENSAMBLE Paso 1 Use las pinzas para colocar cuidadosame...

Страница 18: ...o e inserte el estator al mismo tiempo Use el destornillador plano para presionarlos en su lugar Ver la fig 5 Paso 3 Inserte el resorte la tapa del resorte y el trinquete Sost ngalo con la mano para p...

Страница 19: ...s con el fin de ahorrar potencia Oprima para sacar del modo suspendido MONTAJE REAJUSTE DE LA LLAVE Si la llave no funciona de manera normal oprima a la vez para reajustar la llave 1 Encender Borrar 2...

Страница 20: ...ar una torsi n inicial en el despliegue Algunas de las l mparas se iluminar n y la llave sonar un tono de alarma continuo Para borrar el despligue y parar la alarma oprima el bot n SELECCIONANDO UNIDA...

Страница 21: ...ajustados desde la f brica Indicador de memoria pre ajustado M1 Indicador de memoria pre ajustado M2 Indicador de memoria pre ajustado M3 M4 M5 etc Indicador de memoria pre ajustado M9 Oprima o para...

Страница 22: ...do de retenci n de picos Almacenando los valores de retenci n de picos Modo de retenci n de picos Este modo le permite al operador revisar y almacenar los valores individuales de torsi n Se pueden alm...

Страница 23: ...gar y se convierte en el valor 3 El valor en la ubicaci n 5 se baja al n mero 4 etc Borrando un valor de retenci n de picos Borrando todos los valores de retenci n pico 1 Repita los pasos 1 al 3 anter...

Страница 24: ...DTW14FL 24 Rev 12 11 14 NOTAS Preajuste de memoria Localizaci n Metros Newton N m Pulgadas pie in lb Libras pie ft lb Kilogramo cent metros kg cm ngulo grado 1 2 3 4 5 6 7 8 9...