Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1614: "Savable" entry changed from "yes,
category: application" to "yes, category: tuning".
Description
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TYPE
TYPE
Defines the type of encoder. For a differential encoder, the bit must have the value "0". For a
single-ended encoder, the bit must be set to "1".
205Ah Absolute Sensor Boot Value (in User Units)
Function
The initial encoder position when switching on the controller (in user-defined units) can be read from
this object.
Object description
Index
205A
h
Object name
Absolute Sensor Boot Value (in User Units)
Object Code
VARIABLE
Data type
INTEGER32
Savable
no
Access
read only
PDO mapping
no
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1446
Change history
Firmware version FIR-v1512: "Access" table entry for subindex 00
changed from "read/write" to "read only".
Firmware version FIR-v1738-B501312: "Object Name" entry changed
from "Encoder Boot Value" to "Absolute Sensor Boot Value (in User
Units)".
Firmware version FIR-v1738-B501312: "Data type" entry changed
from "UNSIGNED32" to "INTEGER32".
Version: 1.0.1 / FIR-v1748
165