Technical Manual PD4-E-M (EtherCAT)
3 Technical details and pin assignment
Note
Aside from the motor, the exact temperature behavior is also dependent on the flange connection and
the heat transfer there as well as on the convection in the application. For this reason, we recommend
always performing an endurance test in the actual environment for applications in which current level
and ambient temperature pose a problem.
3.5 LED signaling
3.5.1 Power LED
Normal operation
In normal operation, the green power LED L1 flashes briefly once per second.
1s
2s
3s
4s
5s
6s
7s
8s
9s
Case of an error
If an error has occurred, the LED turns red and signals an error number. In the following figure, the
error number 3 is signaled.
1s
2s
3s
4s
5s
6s
7s
8s
9s
3x
The following table shows the meaning of the error numbers.
Flash rate
Error
1
General
2
Voltage
3
Temperature