![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520074.webp)
Manual PD4-C (USB)
10 Special functions
Version: 1.4.1 / 22.07.2016 / FIR-v1626
74
current
t1
t2
t1
Lim
t2
Lim
I
2
t
I
2
t
t
Maximum
current
Nominal
current
In the first section t1, the current value is higher than the nominal current. At time t1
Lim
, I
2
t
Lim
is reached
and the current is limited to the nominal current. During the following time period t2, a current comes
that corresponds to the maximum current. Accordingly, the value for I
2
t
Lim
is reached faster than in time
period t1.
10.3 Save Objects
Objects can only be saved with the file
pd4cfg.txt
, the save mechanism with the object 1011
h
and
1010
h
is deactivated with this controller. Aside that a NanoJ program can access the object 2700
h