Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
205
Sub-index
01
h
Name
Min Position Limit
Data type
INTEGER32
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
80000000
h
Sub-index
02
h
Name
Max Position Limit
Data type
INTEGER32
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
7FFFFFFF
h
Description
The target position must lie within the limits set here. Before the check, the home offset (607C
h
) is
deducted in each case:
Corrected min position limit = min position limit - home offset
Corrected max position limit = max position limit - home offset.
607Eh Polarity
Function
This object can be used to reverse the direction of rotation.
Object description
Index
607E
h
Object Name
Polarity
Object Code
VARIABLE
Data type
UNSIGNED8
Saveable
yes, category: application
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00
h
Firmware Version
FIR-v1426
Change History
Description
The general rule for direction reversal is: Reversal is activated if a bit is set to the value "1". If the value
is "0", the direction of rotation is as specified in the respective mode
POS
VEL
7
6
5
4
3
2
1
0