![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 157](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520157.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
157
Description
•
Sub-index 00
h
: Number of entries
•
Sub-index 01
h
: Proportional value of the S (position) control
•
Sub-index 02
h
: Integral value of the S (position) control
•
Sub-index 03
h
: Proportional value of the V (velocity) control
•
Sub-index 04
h
: Integral value of the V (velocity) control
•
Sub-index 05
h
: (Closed Loop) Proportional value of the current controller for the field-forming
component
•
Sub-index 06
h
: (Closed Loop) Integral value of the current controller for the field-forming component
•
Sub-index 07
h
: (Closed Loop) Proportional value of the current controller for the torque-forming
component
•
Sub-index 08
h
: (Closed Loop) Integral value of the current controller for the torque-forming
component
•
Sub-index 09
h
: (Open Loop) Proportional value of the current controller for the torque-forming
component
•
Sub-index 0A
h
: (Open Loop) Integral value of the current controller for the torque-forming
component
3212h Motor Drive Flags
Function
This object determines, whether the output voltage for the motor is active in state "switched on" of the
DS 402 Statemachine or not. Furthermore the direction of rotation of the rotating field can get changed.
Note
Changes in sub-index 02 are valid after a reset of the controller.
Object description
Index
3212
h
Object Name
Motor Drive Flags
Object Code
ARRAY
Data type
INTEGER8
Saveable
yes, category: application
Access
Read only
PDO Mapping
No
Admissible Values
Specified Value
Firmware Version
FIR-v1450
Change History
Firmware Version FIR-v1512: Amount of subentries has changed from
2 to 3.
Firmware Version FIR-v1540: Amount of subentries has changed from
3 to 4.
Value description
Sub-index
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
Read only