![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 119](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520119.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
119
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
0000003C
h
Firmware Version
FIR-v1426
Change History
Description
The internal operand pertains to full mechanical (2060
h
=0) revolutions per
second.
Thus, by setting object 2065
h
h
=60, for example, the acceleration can be specified in
(revolutions/min)/s
2
in profile position mode.
2067h Jerk Limit (internal)
Function
This object controls the calculation for the real jerk limit, this limit is deactivated if this object is set to
the value "0".
The following formula describes the calculation of the real jerk limit:
Jerk Limit Real =
Jerk limit internal (2067
h
) x Jerk denominator (2066
h
)
2048 x Jerk numerator (2065
h
) x Pole Pair Count (2030
h
)
Object description
Index
2067
h
Object Name
Jerk Limit (internal)
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: application
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00989680
h
Firmware Version
FIR-v1450
Change History
2084h Bootup Delay
Function
This object allows specification of the time period between when the supply voltage is applied to the
motor controller and the provision of operability of the motor controller in milliseconds.
Object description
Index
2084
h
Object Name
Bootup Delay