![NANOTEC PD4-C Скачать руководство пользователя страница 246](http://html1.mh-extra.com/html/nanotec/pd4-c/pd4-c_technical-manual_3241514246.webp)
9 Description of the object dictionary
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00001388
h
Firmware version
FIR-v1426
Change history
60F2h Positioning Option Code
Function
The object describes the positioning behavior in Profile Position mode.
Object description
Index
60F2
h
Object name
Positioning Option Code
Object Code
VARIABLE
Data type
UNSIGNED16
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
0001
h
Firmware version
FIR-v1446
Change history
Firmware version FIR-v1614: "Savable" entry changed from "no" to
"yes, category: application".
Description
Only the following bits are supported at the present time:
RADO [2]
MS
RESERVED [3]
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RRO [2]
CIO [2]
REL. OPT. [2]
IP OPTION [4]
REL. OPT. (Relative Option)
These bits determine the behavior with relative rotating movement in "profile position" mode if bit 6 of
controlword 6040
= "1" is set.
Bit 1
Bit 0
Definition
0
0
Position movements are executed relative to the previous (internal
absolute) target position (each relative to 0 if there is no previous target
position)
0
1
Position movements are executed relative to the preset value (or output)
of the ramp generator.
1
0
Position movements are performed relative to the current position (object
6064
).
Version: 2.0.1 / FIR-v1650
246