![NANOTEC PD4-C Скачать руководство пользователя страница 158](http://html1.mh-extra.com/html/nanotec/pd4-c/pd4-c_technical-manual_3241514158.webp)
9 Description of the object dictionary
Object description
Index
2400
h
Object name
NanoJ Inputs
Object Code
ARRAY
Data type
INTEGER32
Savable
no
Firmware version
FIR-v1426
Change history
The number of entries was changed from 2 to 33.
Firmware version FIR-v1436: "Object Name" entry changed from
"VMM Inputs" to "NanoJ Inputs".
Firmware version FIR-v1436: "Name" entry changed from "VMM Input
N#" to "NanoJ Input N#".
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
20
h
Subindex
01
h
- 20
h
Name
NanoJ Input #1 - #32
Data type
INTEGER32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000000
h
Description
Here, it is possible to pass, e.g., preset values, to the NanoJ program.
2410h NanoJ Init Parameters
Function
This object functions identically to object 2400
h
with the difference that this object can be stored.
Object description
Index
2410
h
Object name
NanoJ Init Parameters
Object Code
ARRAY
Version: 2.0.1 / FIR-v1650
158