![NANOTEC PD4-C Скачать руководство пользователя страница 144](http://html1.mh-extra.com/html/nanotec/pd4-c/pd4-c_technical-manual_3241514144.webp)
9 Description of the object dictionary
2063h Acceleration Numerator
Function
Contains the counter that is used for converting from user-defined acceleration values to the internal
revolutions/second
2
. See chapter User-defined units.
Object description
Index
2063
h
Object name
Acceleration Numerator
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000001
h
Firmware version
FIR-v1426
Change history
2064h Acceleration Denominator
Function
Contains the denominator that is used for converting from user-defined acceleration values to the internal
revolutions/second
2
. See chapter User-defined units.
Object description
Index
2064
h
Object name
Acceleration Denominator
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
0000003C
h
Firmware version
FIR-v1426
Change history
2065h Jerk Numerator
Function
Contains the counter that is used for converting from user-defined jerk values to the internal revolutions/
second
3
. See chapter User-defined units.
Version: 2.0.1 / FIR-v1650