Technical Manual N5 (CANopen)
4 Commissioning
Starting NanoIP
1. Connect controller (connector X1) and PC.
2. Connect voltage supply to connector X6 of the controller.
3. Wait until the boot process of the controller has concluded (LED L1 flashes once per second).
4. The controller is depicted in the network area of Windows Explorer after the scan operation (naming
convention is "
N5-44AAE8
" followed by 6 hexadecimal digits, e.g., "
N5-44AAE8123456
discovery and the UPnP service must be activated. Double-click to open the NanoIP web server in
the web browser.
Parameter input
1. Start the NanoIP web server.
2. Select the OBJECT DICTIONARY menu item.
3. Enter all values in the corresponding objects.
4. Use the Download settings button to transfer the values to the controller.
5. Select the SETUP->Configuration menu item
6. Use the Save Complete Configuration button to permanently save the values in the controller.
4.2 Configuration via CANopen
4.2.1 Communication settings
Described in the following chapters is how you can change the communication settings.
The controller is configured per default for node-ID 1 and a baud rate of 1 Mbaud.
Setting node-ID and baud rate
Node-ID and baud rate are dependent on the position of the S1 and S2 rotary switches and, if
applicable, on objects 2005h CANopen Baudrate, and 2009h CANopen NodeID.
Rotary switch
The N5 is equipped with two hex coding switches – similar to that shown in the following figure.
You can set the source for the CANopen node-ID and the baud rate using the combination of numbers
from both rotary switches.
The following applies here: the combination of numbers is formed using rotary switches S1 and S2,
where S1 represents the higher-value byte and S2 the lower-value byte.
Example
Switch S1 is set to the value "0
h
", switch S2 to the value "F
h
"; the result is the value
"0F
h
"="16
d
".
Switch S1 is set to the value "A
h
", switch S2 to the value "1
h
"; the result is the value
"A1
h
"="161
d
".
Version: 2.0.1 / FIR-v1650
34