![NANOTEC ELECTRONIC N5 Скачать руководство пользователя страница 221](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153221.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
The corresponding adjustment value is then
FFFFFF00
h
.
2014h Current-IPv4-Address
Function
Contains the currently active IP address in the form of a 32-bit word.
Object description
Index
2014
h
Object name
Current-IPv4-Address
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
no
Access
read only
PDO mapping
no
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1450: "Object Name" entry changed from
"Current-IP-Address" to "Current-IPv4-Address".
Description
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
IP Address Part 2 [8]
IP Address Part 1 [8]
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
IP Address Part 4 [8]
IP Address Part 3 [8]
IP Address Part 1 [8]
Specifies the first part of the IP address
IP Address Part 2 [8]
Specifies the second part of the IP address
IP Address Part 3 [8]
Specifies the third part of the IP address
IP Address Part 4 [8]
Specifies the fourth part of the IP address
Example
Address
192.168.2.0
is first converted to hexadecimal format, resulting in the following
configuration value:
192 => C0
h
168 => A8
h
Version: 2.0.1 / FIR-v1650