![NANOTEC ELECTRONIC N5 Скачать руководство пользователя страница 190](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153190.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Subindex 4 (compatibility entry): This subindex has no function and exists only for compatibility
reasons.
Subindex 5 (event timer): This time (in ms) can be used to trigger an Event which handles the copying
of the data and the sending of the PDO.
For details, see chapter on configuring the TX-PDO mapping.
1807h Transmit PDO 8 Communication Parameter
Function
Contains the communication parameters for the sending-side mapping (TX-PDO) 8. See chapter
Process Data Object (PDO).
Object description
Index
1807
h
Object name
Transmit PDO 8 Communication Parameter
Object Code
RECORD
Data type
PDO_COMMUNICATION_PARAMETER
Savable
yes, category: communication
Access
read only
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1614
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
05
h
Subindex
01
h
Name
COB-ID
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
C0000000
h
Subindex
02
h
Version: 2.0.1 / FIR-v1650