![NANOTEC ELECTRONIC N5 Скачать руководство пользователя страница 173](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153173.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Name
8th Object To Be Mapped
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
1606h Receive PDO 7 Mapping Parameter
Function
This object contains the mapping parameters for PDOs that the controller can receive (RX-PDO 7). The
PDO was previously configured via 1406h Receive PDO 7 Communication Parameter. See chapter
Process Data Object (PDO).
Object description
Index
1606
h
Object name
Receive PDO 7 Mapping Parameter
Object Code
RECORD
Data type
PDO_MAPPING
Savable
yes, category: communication
Access
read / write
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1614
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read / write
PDO mapping
no
Allowed values
Preset value
00
h
Subindex
01
h
Name
1st Object To Be Mapped
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Version: 2.0.1 / FIR-v1650