NANO SEPURA SEP 1250 ST Скачать руководство пользователя страница 1

Before star  ng assembly, please check    
contents are as follows:

 1

   white felt bag fi lter with black tube

 

1

   STERLING fi lter (bag 1)

 

1

   white fi lter (bag 2)

 

  test bo  le

 

2

   metal retaining springs (460 mm)

 

1

  cleaner tower

 

drilled lid

service interval kit containing:

 

 molded plas  c mount + screw

 

 printed card

 

 self-adhesive   mestrip

fi    ng kit containing:

 

1

   straight adaptor 15 mm x 1/2” BSP

 

1

   blanking plug - large

 

1

   elbow 15 mm

 

1

   assembled por  ng block

• 

3

   por  ng block small blanking plugs

 

4

   screw 4.8 x 45 mm and washers

 

2

   grab taps

 

1

   blue nylon adaptor

 

1

   black tube (15 x 200 mm)

Insert the boss on the reverse 
of the mount 

(c)

 into the pre-

drilled hole in the separator lid.

Peel backing from   mestrip

 (a) 

and a  ach to the plas  c card 

(b) 

within the do  ed lines.

Flex the card, passing the ends 
through the slots on the top 
surface of the mount.

To ac  vate, 

press fi rmly on 

the   mestrip label at the point 
indicated.

A  er a few minutes, a red line 
will appear, to indicate ‘  me in 
service’ up to 12 months.

A replacement card and   me-
strip will be supplied with each 
service kit.

installation manual
SEP 1250 ST

1

service indicator - 

assembly and a  achment

general installa  on notes

(b)

(c)

(a)

i

ii

iii

•  Please ensure a steady fall in the 
pipe run from the outlet point to the 
sanitary drain.

•  When used in conjunction with 
timed solenoid drain, set drain “open” 
duration to minimum setting (1-2 
seconds).

•  When used in conjunction with 
motorized ball valve or high capacity 
drain (ie Drain-all®) a de-pressur-
ization chamber must be installed 
between drain and Sepura unit.

•  Never discharge  condensate to a 
storm drain or to suface water; always 
connect to a sanitary drain or sewer.

•  Remember that it’s the user’s 
responsibility  to check with the local 
authority as to the permissible dis-
charges in their area.

tes  ng quality

Replace fi lters before 
outlet cloudiness 
exceeds the ppm limit 
for your region.

Test outlet quality 
weekly using kit 
provided.

Отзывы: