Page 20
17-110 -0143
10.3 Service Schedule
Service
Recommended Service Intervals
12 Months
(or 8,000
hours)
24 Months
(or 16,000
hours)
36 Months
(or 24,000
hours)
48 Months
(or 32,000
hours)
60 Months
(or 40,000
hours)
72 Months
(or 48,000
hours)
84 Months
(or 56,000
hours)
96 Months
(or 64,000
hours)
A
P
P
P
P
P
P
P
P
B
P
P
P
P
C
P
P
P
P
D
P
P
Service A (A-XXX-1X0):
1” External exhaust silencer/muffler (
Available in either BSP or NPT
)
NITROGEN
GENERATOR
MODEL
SERVICE CODE
A
B
C
D
E
F
6 - 10 barg
[87 - 145 psig]
10.5 - 16 barg
[152 - 232 psig]
GEN2- 1110
A-BSP-110
A-NPT-110
A-BSP-130HP
A-NPT-130HP
B-SSVK-130
C-PVSK-130
D-CVK-130
E-GCR-%
E-GCR-PPM
F-ZCR-%
F-ZCR-PPM
GEN2- 2110
GEN2- 3110
GEN2- 2130
A-BSP-130
A-NPT-130
GEN2- 3130
GEN2- 4130
GEN2- 6130
GEN2- 8130
GEN2- 10130
GEN2- 12130
Oxygen Analyzer Recommended Service Intervals
E
Galvanic Cell
P
P
P
P
F
Zirconian Cell
P
Service A (A-XXX-130HP):
2” External exhaust silencer/muffler (
Available in either BSP or NPT
)
Note: The Serial/Part number of the nitrogen generator must be supplied when requesting any of
the services listed above, this is to
ensure the correct service parts are selected.
Service B (B-SSVK-130):
O
2
Sensor Solenoid Valves (
2 required If fitted with a Galvanic Cell
)
Service C (C-PVSK-130):
All piston valve seals are to be replaced
Service D (D-CVK-130):
All control valves are to be replaced.
Service E (E-GCR-%):
Replace % O
2
Sensor (Galvanic Cell)
Service F (F-ZCR-%):
Replace % O
2
Sensor (Zirconian Cell)
Service E (E-GCR-PPM):
Replace PPM O
2
Sensor (Galvanic Cell)
Service F (F-ZCR-PPM):
Replace PPM O
2
Sensor (Zirconian Cell)
Содержание GEN2-1110
Страница 1: ...GEN2 NITROGEN GENERATOR USER GUIDE...
Страница 23: ...Page 23 17 110 0143 14 Electrical Schematic 14 1 GEN2 1110 2110 3110 2130 3130 4130 6130 8130 10130 12130...
Страница 26: ...Page 26 17 110 0143 Notes...
Страница 27: ...Page 27 17 110 0143 Notes...