FR15 Synchronizing Control Box

FR15-E3-V12

1 /

 

3

 
 
 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Application 

Design for the fault alarm output,ON/OFF and flash frequency control for aviatioon obstruction light. 

Major functions&features 

•    Control the aviation lights flash synchronously. 
•    With fault alarm function. When any light fails, there will be with alarm indicator and fault signal 

output. 

•    Alarm signal is relay contactor output, no power source.   
•    With photocell/manual switchover device. If you do not need photocell function, it could change 

to manual control model by this device. 

••    Light-operated switch use PJ003 to realize its function. Fault alarm function about photocell can 

be customized. 

•    AC type control box can customize the GPS synchronization: Synchronize all aviation lights 

which are controlled by different control box.   

•   With  disturbance  switching  function.  When  lead  light  fails,  standby  light  will  switch  on 

automatically.(Customized). 

Specification 

 

Voltage

 

DC48V 
AC110V~AC240V 

Control method

 

Steady burning/flash

 

Control circuit 

branch

 

4 ways

 

Flash frequency

 

20~60

 times/minute

(adjustable)

 

Photocell sensitivity

70~100Lux(on/off) 

Alarm output

 

dry connect(relay) output

 

 

Ambient 

temperature

 

-30˚C ~ +70˚C 

IP code 

IP65 

Humidity

 

10% ~ 95% (

no coagulation

) 

Wiring Connection   

•Power connetion terminal. Product has AC and DC type. Please see the following diagram: 

  

 

•Aviation light’s connction terminal. Product has AC and DC type. Please see the following 
diagram

       

 

For control box with faulty switch over function, Light 1 is lead light’s outputting, Light 2 is 

standby light’s outputting. When Light 1 works, Light 2 is rest. In case Light 1 fails, Light 2 
start to work automatically.   

 

••    Connection terminal of aviation light’s faulty alarm. When light fails, this terminal will be 

closed. Following diagram is “Light1 fault” terminal. 

 

 

•    Please see following diagram for photocell connection terminal. 

 

Operation:

 

•    Manual/Automatic switchover: 
      Set the dial switch to the left side, the control panel is in auto status. In this case, control 

box will switch on/off the lights at nighttime/daytime automatically. Set the dial switch to 
the middle, control box is in manual status. In this case, the lights will work. Set the dial   

 

 
                                                                               
Installation(unit:mm) 
 

   

                                                                               
Connection diagram 

 

               
                                   
 
 
 
                   
 
 

FR15 

Series 