© by N&W GLOBAL VENDING S.p.A.
30
06 2007 294-00
poWER Supply uNit
The power supply unit is housed in the payment system
compartment; the fuses and the compartment switch
can be accessed directly, while it is necessary to remove
the metal protective casing to access the connectors
located on the front panel of the power supply unit.
When replacing any fuses the power supply cable
must be disconnected from the power outlet.
Fig. 26
Line fuses
1-
Transformer primary winding protection fuse
2-
CPU board power supply connector
3-
Lamp connector
4-
Compressor and fan connector
5-
Protection fuse for secondary winding
6-
Protection fuse for secondary winding
7-
Payment system compartment switch
8-
accESS to thE cooliNg uNit
If for any reason the cooling unit need to be accessed
from the machine, do as follows:
- remove the last tray;
- remove the anti-intrusion grille;
- undo the fastening screws from the product dispensing
compartment and remove it.
- For reassembly, proceed in the reverse order.
Fig. 27
Anti-intrusion grille
1-
Dispensing compartment
2-
Photocell support
3-
Fig. 28
Evaporator
1-
Fan
2-
Condenser
3-
Dispensing compartment
4-