Schedule setting method 2: on System Setting Interface, meanwhile the device is under Auto Mode , short press
button to enter into Auto Mode Schedule weekly setting interface quickly:
On Auto Mode Schedule weekly setting interface, use buttons and to enter into schedule setting of a certain
week as follows:
F
For each schedule, the latter time should be later than the former time, otherwise saving will fail with the error remind
“Time setting error!!!”. The default time schedules are as follows:
For example, in order to quickly dry the water on the floor of the bathroom, the device can be set to quickly heat in a
short time to dry the floor. Enter the configuration interface as follows:
Duration: set how long the dry mode lasts, can be configured through the proprietary attribute DryTime (0x1006) of
Thermostat Cluster (0x0201), the configurable range is 5-100 minutes.
After Mode: set the mode after the drying mode ends, can be configured through the proprietary attribute ModeAfter-
Dry (0x1007) of Thermostat Cluster (0x0201).
Remain: shows the remaining time of the drying mode
For configuration method and modification, please refer to Automatic Mode (Energy Save
Mode) Schedule:
3. Manual Mode:
the device will control the heating system according to current set temperature. The temperature can be
set by move up and move down button on the Home interface, or configured by Zigbee gateway.
4. Dry Mode Schedule
Once the device is powered on and stable, referring to the room temperature sensor, if the temperature
decreases to the threshold of this setting, the window open mark will be enabled, the relay will be forced to turn
off to save energy, then the icon will appear.
After window open mark is enabled, if the temperature increases to the threshold of this setting in 3 minutes, the
window open mark will be disabled.
Once the window open mark is enabled, it will be disabled after 10 minutes, and the device will keep current working
mode.
This value can also be configured through the proprietary attribute WindowOpenCheck (0x1009) of Thermostat
Cluster (0x0201), 0 means this function is disabled.
Note: this function will work better when the device is installed beside the window or door.
Window Open Detect (disabled by default)
5.Off Mode
This mode means that the device is under idle status.
Monday-Friday
7:30,24C-12:00,20C
18:00,16C-22:30,18C
Saturday-Sunday
7:30,24C-12:00,20C
18:00,18C-22:30,18C
On Auto Day Schedule interface, short press button to select the time or temperature that
you would like to modify, then short press move up and move down buttons to modify
value, then short press button to save and quit, short pressing button only quits without
saving.
F