Page 57
Never use any solvent products to clean the Fibre Optic Cable as the solvent
may cause irreparable damage.
Clean the end of the Fibre-Optic Cable regularly. If the end of the
Fibre-Optic Cable becomes dirty, the Target Assys may not detect the light
emitted from the Gun Assy, and fail to register a hit correctly.
Do not touch the Xenon Tube in the Xenon Assy with your fingers during
cleaning as the natural oils in the skin may shorten the life of the Xenon
Tube. If you do touch the Xenon Tube with your fingers, wipe the Xenon
Tube thoroughly with isopropyl alcohol.
(Part No 95000031)
1.
Remove the Fibre Optic Cable as described in
section 8-14-1 (1-3) page 77
2.
Wipe and clean the surface of the Fibre Optic Lens with a clean, dry, lint
free cloth.
3.
Reassemble in reverse order.
Note: To ensure sufficient light emission from the Gun Assy, refit the
Fibre Optic Cable as close to the Xenon Tube as possible.
Soft, dry cloth
Fibre optic
Fiber Optic Cable
Holder
Xenon Tube
Xenon PC Board
When refitting, push the
Fiber Optic in until the end
comes into contact with
the stopper in the holder
Stopper