Chapter 1 Serial Commands
The user can configure the reading module by sending serial commands from the host . The normal
communication between the reading module and the host device can only be realized when the communication
parameter configuration is completely matched .
The default serial communication parameters of the reading module are as follows :
parameter
Default parameter value
baud rate
9600bps
Check Digit
no verification
data bits
8 bits
stop bit
1 person
hardware flow
control
No flow control
1.1 Read flag bit operation
For the read operation of device flag bits, up to 256 bytes of flag bits can be read at one time .
Command format :
Input : {Head1} {Types} {Lens} {Address} {Datas} {CRC}
Among them :
Head1 : 0x7E 0x00 (2 bytes)
Types : 0x07 (1 byte)
Lens : 0x01 (1 byte)