background image

SIZE:36"  x 48"

DSR543648C-CL

48

" x 

36

" Rolling Rectangular Sliding Shower Door

Dimension of shower door: 

Profile adjustment: +25mm/1"

Rail adjustment :-80mm/3-1/8"

1981mm(78")

870~895mm

(34-1/4"~35-1/4")

1235~1172mm

(48-1/2"~46")

Rev.DEC 16,2020

(870~895)  x (1235~1172) x 1981mm(H) / (34-1/4"~35-1/4") x (48-1/2"~46") x 78"(H) 

Содержание DSR543648C-CL

Страница 1: ...ctangular Sliding Shower Door Dimension of shower door Profile adjustment 25mm 1 Rail adjustment 80mm 3 1 8 1981mm 78 870 895m m 34 1 4 35 1 4 1235 1172mm 48 1 2 46 Rev DEC 16 2020 870 895 x 1235 1172...

Страница 2: ...yants vitre peuvent tre utilis s mais avec pr caution Dans le doute contactez le manufacturier du produit en question After use your shower should be cleaned with soap and water This is particularly i...

Страница 3: ...Quantit Item no in exploded num ro d items dans la vue expos e Description Square Wall Joints L R Bouchons de mur Wall Caps Bouchons de vis Screw Cover Caps Bouchon De Mur Wall Plugs Chevilles Screws...

Страница 4: ...can be made after the door installation crou excentrique pour l ajustement des roulettes L ve et baisse la roulette L espace minimum devrait tre orient vers le bas tel qu illustr Ajustements peuvent t...

Страница 5: ...ES ON THE SIDE OF THE WALL JAMB MUST FACE THE INTERIOR OF THE SHOWER LES TROUS SITU SUR LE C T DU JAMBAGE DOIVENT TRE ORIENT S VERS L INT RIEUR DE LA DOUCHE Make sure your measurements are correct and...

Страница 6: ...ouvrir les dents de la pince pour ne pas rayer le m tal B C Adjust using both sizes and combinations of clear setting blocks if necessary Ajuster l aide des deux tailles de blocs de niveau transparent...

Страница 7: ...s deux tailles de blocs de niveau transparents et leurs combinaisons si n cessaire 22 A Note this screw should face the inside of the shower Remarque Cette vis doit faire face l int rieur de la douche...

Страница 8: ...27 B mm A2 46mm 28mm A1 A C1 D C1 C2 C2 Screw M4x35 Vis m4x35 fixed panel Panneau fixe fixed panel Panneau fixe fixed panel Panneau fixe fixed panel Panneau fixe INTERIOR SHOWER SIDE INT RIEUR DE LA...

Страница 9: ...A DOUCHE Hold eccentric nut in place with wrench while tightening the small nut Tenir l crou excentrique en place avec la cl tout en serrant le petit crou Level the door panel by rotating the eccentri...

Страница 10: ...13 tape 13 Step 14 tape 14 9 Do not forget the gaskets Ne pas oublier les joints 7 INTERIOR SHOWER SIDE INT RIEUR DE LA DOUCHE 24 INTERIOR SHOWER SIDE INT RIEUR DE LA DOUCHE TOP VIEW VUE DU HAUT 5 2 4...

Страница 11: ...3 B1 INTERIOR SHOWER SIDE INT RIEUR DE LA DOUCHE 16 11 21 3 2mm A A A 11 cut the rail according to the actural measurment couper le rail selon la mesure r elle Size for reference only La grandeur est...

Страница 12: ...Step 17 tape 17 11 Allow 24 hours for silicone to dry before use Attendez 24 heures pour que le silicone soit sec avant utilisation 24 hours 24 heures...

Страница 13: ...BS RT3648L PP PP PP PP PP PP PP PP PP PP PP PP P P 6 3 2 This indentation is designed to ensure the water goes back to the shower base towards the drain HWWH IHQWH HVW FRQoXH SRXU SHUPHWWUH j O HDX GH...

Страница 14: ...lors de l installation Avant l installation de la base toute la charpente et les travaux de plomberie doivent tre compl t s conform ment la pr sente feuille d instruction Pour les travaux de r novatio...

Страница 15: ...A B C D 90 A 02 C 90 D Enlever la p llicule de plastique protectrice Remove protective plastic film A 01 BASE INSTALLATION INSTALLATION BASE SUITE CONTINUED 3 A 03...

Страница 16: ...SUITE CONTINUED FORET 1 8 1 8 DRILL BIT A 05 A 04 SUITE CONTINUED 4...

Страница 17: ...GH FlUDPLTXH HUDPLF WLOHV SVH SVLXP 6LOLFRQH 0RQWDQW PXUDO DOO VWXG 9LV 5 HI 6FUHZ 5HI VUE SECTIONNELLE SIDE SECTION VIEW A 07 Pellicule Film Base Base Mor er Mortar A 06 9LV 6FUHZ SUITE CONTINUED SU...

Страница 18: ...er votre porte de douche afin de permettre au mortier et la finition de s cher compl tement WARNING Wait 24h before proceeding with the installa tion of the shower door This will ensure that the finis...

Страница 19: ...of God or breakage resulting from a shock or mishandling regardless of the part played by the buyer or the installer It also excludes the damages caused by an improper installation NADOLI doesn t cove...

Страница 20: ...rantie ne couvre pas les dommages caus s par les actes de Dieu ou les bris r sultant d un choc ou d une mauvaise manutention Elle exclut aussi les dommages qui r sultent d une mauvaise installation D...

Отзывы: