14 of 32
Opus Control Wiring and Programming Installation Manual
www.NabcoEntrances.com
P/N C-00139
Rev 10-20-17
History Settings
Parameter
Description
Operation Cnt
X
Indicates number of Door open cycles.
X
Updated every 100 door cycles.
Open Recycle Cnt
Indicates number of times the Door reversed direction during Opening cycle after sensing:
X
An object was struck.
X
The amount of friction that surpassed the recycle sensitivity setting.
Close Recycle Cnt
Indicates number of times the Door reversed direction during Closing cycle after sensing:
X
An object was struck.
X
The amount of friction that surpassed the Recycle Sensitivity Setting.
Latest Recycle Position
X
Indicates the last recycle position during opening and closing.
X
For swing doors it displays the approximate angle from closed at recycle. For slide doors it displays
the position in inches from closed.
Test Open
Tests Open/Close door cycle while ignoring Safety Signals.
CHAPTER 9: COMMON PROGRAM ADJUSTMENTS
SECTION 9.1: Stroke Learning
UNIT SPECS
Passcode
Go to Se ng menu
Stroke Learning
Yes No
Push and Hold
Rotary Dial (2 Sec.)
LEVEL 1
LEVEL 2
1. Rotate Dial to select
"Yes".
2. Push Rotary Dial
3. Door will Fully Close
Open Door
DN 1633
SECTION 9.2: Movement Settings
DN 1635
UNIT SPECS
Passcode
Go to Se ng menu
Stroke Learning
Yes No
Push and Hold
Rotary Dial (2 Sec.)
LEVEL 1
LEVEL 2
1. Rotate Dial to select
"Go to Se ng menu".
2. Push Rotary Dial
Se ng Category
LEVEL 3
Movement Se ng
Push Rotary Dial
Open Speed
0 1 2 3 4 5 6 7
0, 1 = Slow, 7 = Fast
Speed Ajustment
11
20
10
12
1. Rotate Dial to select the
"parameter op on".
2. Push Rotary Dial
1. Rotate Dial to select
"speed in seconds".
2. Push Rotary Dial
LEVEL 4
1. Rotate Dial to select
"Movement Se ng".
2. Push Rotary Dial
Back Check Speed
0 1 2 3 4 5 6 7
0, 1 = Slow, 7 = Fast
Speed Ajustment
11
20
10
12
Push and Hold