SECTION 5.1 Stroke Learning (YES)
1. Go to the Opus Control. From the Unit Specs Screen, press down on the Rotary Dial until the next Screen is displayed.
2. Turn the Rotary Dial to highlight (YES) under (Stroke Learning).
3. Briefly press down on the Rotary Dial.
a . The Control will check to see if the Door is fully
Closed
→
then slowly Open
→ Close again
SECTION 5.2 Error Message
If Handing of Door is wrong, messages after the Stroke Learning Cycle will display: “Wrong Hand! Restroke” . If this event occurs
one of two things are indicated:
X
The wrong Operator Type is selected
X
The wrong Handing is selected.
If the wrong Handing is selected for:
X
The GT710 Door, enter the proper settings within the Base Setting Category screens.
X
All other Swing Doors, Handing is changed by adding or removing the Handing Harness.
CHAPTER 6: SIMULTANEOUS PAIR, DOUBLE EGRESS, AND BI-FOLD DOORS
Attention: DO NOT copy data from a Type 1 control. If data is copied from a Type 1 control:
►
The Type 1 control will change itself to a Type 2 control.
►
There will be no communication between controls of the same Type.
Attention: When programming Opus controls on bi-fold doors using 2 controls, Always say “NO” to “copy data?”.
Since monitored sensors are only connected to one control (Type 2), you don’t want the monitoring
settings to be copied to the control without sensors connected (Type 1).
Any changes to one control, such as speed or timing, should be entered on the other control
manually, not copied.
Note: Simultaneous Pair settings apply to any Simultaneous Pair, or Double Egress having (2) Operators.
Note: Units are setup to operate as a pair at the NABCO Factory and shipped accordingly.
Note: For Headers with stacked Opus Controls, the Type 2 Control is always installed on top of the Type 1 Control.
Within the Status Screen (main screen) located at the top, Opus Controls are labeled Type 1 or Type 2. Type 1 should be considered
the Slave Control; Type 2 should be considered the Master Control:
X
All Activation Devices are connected to the Type 2 (Master Control).
X
Programming/Settings that need to apply to both Controls, are done from the Type 2 (Master Control).
X
To ensure programming/settings made to the Type 2 (Master Control) is copied to the Type 1 (Slave Control), select YES
when prompted to COPY DATA. This is done when backing out of programming.
DN 2270
11
20
10
12
Type: 1
GT710 Swing
Status:
Slow Closing
Error:
-----
Ac va on:
IN EXT
Posi on:
> > > > > > >
Other:
BA 6B SWL
Push and Hold Dial
Go to Se ng Mode
11
20
10
12
Type: 2
GT710 Swing
Status:
Slow Closing
Error:
-----
Ac va on:
IN EXT
Posi on:
> > > > > > >
Other:
BA 6B SWL
Push and Hold Dial
Go to Se ng Mode
STATUS
SCREEN
2 = Master Control
STATUS
SCREEN
1 = Slave Control
OPUS Control
Fully Closed
Fully Closed