background image

 

 

 

 

 

 

 

 

 

 
 
 

 
 
 

 

 
 
 
 
 

 

900 Series  

Industrial Ethernet 

Switch 

 

Installation 

& User’s Guide 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 900-N Series

Страница 1: ...900 Series Industrial Ethernet Switch Installation User s Guide ...

Страница 2: ...Rev050908 2 ...

Страница 3: ...e 900B 900N 3 Slot Enclosure and Backplane 900B FP Filler Panel for empty slots 908TX Module 902FX SC Module 902FX ST Module 902FXE SC YY Module 902FXE ST YY Module 904FX SC Module 904FX ST Module 904FXE SC YY Module 904FXE ST YY Module Where YY 15 40 or 80 ...

Страница 4: ... limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Warning Do not perform any services on the unit unless qualified to do ...

Страница 5: ...les during periods of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Do not block the air vents WARNING Observe proper DC Voltage polarity when installing power input cables Reversing voltage polarity can cause permanent damage to the unit and void the warranty LASER SAFETY 904FXE and 902FXE Only WARNING CLASS 1 Laser Product Do not stare into ...

Страница 6: ... with Local National Codes of Authorities Having Jurisdiction 4 Power must be supplied by an isolating source and a 3 3A max rated UL recognized fuse must be installed immediately before the unit 5 Class I Div 2 installations require that all devices connected to this product must be UL listed for the area in which it is installed 6 Only UL listed wiring with temperature ratings greater than 90O C...

Страница 7: ...so supports MDIX auto sensing for auto connector of straight through or crossover cables and provides 8 Category 5 compliant 10 100 BaseT connections for high performance network design and hub repeater upgrades The 902FX is a two port 100Mb module that supports multimode fiber ST and SC connectors are available The 902FXE is a single mode laser version of the 902FX and can support distances of up...

Страница 8: ...on WARNING The 902FXE and 904FXE unit contain a class 1 laser Do not stare into the laser beam fiber optic connector when installing or operating the product Never install or work on electrical equipment or cabling during periods of lightning activity Disconnect the power cable before removing the enclosure top Do not operate the unit with the top cover removed UNPACKING Remove all the equipment f...

Страница 9: ... If Half Duplex operation is desired then follow these steps using proper wrist strap grounding techniques 1 Remove the power power plugs from the unit 2 Loosen all thumbscrews remove all modules 3 Remove the six screws holding the backplane 4 Remove the backplane 5 Move the jumper JP1 from position 1 2 to 3 4 6 Re install the backplane modules power plugs 902 904 Note Rev C D boards are hard wire...

Страница 10: ...y ssembly P N urface bly P N 90 Rail Recess for TX mode al DIN Rail lange of the aps into plac m industrial unit from t ely remove i were designe y not be su N 900 PM 00 RM may the unit to els Note Place the to DIN Rail at ce DIN Rails the DIN Ra it d to be mou uitable for may be use y be used to m allow at lea This unit m op edge of th t a 15 angle Apply dow ail Then ro unted on ind all applicat ...

Страница 11: ...ssis Configure all modules as follows JP1 pins 3 4 shorted JP2 pins 3 4 shorted 908TX Module At power cycle all LED s flash on for approximately two seconds and then return to proper state Green LED will light when Power is connected 902FX 904FX Modules At power cycle only the LED s on the first port flash on to indicate the reset condition and then return to their proper state All other reports r...

Страница 12: ...The table below describes the operating modes LED Color Description GREEN Power is Applied OFF Power is OFF LNK GREEN Link between ports established OFF No Link between ports ACT GREEN Data is active between ports OFF Data is inactive between ports 908 Module Jumper Settings JP1 install jumper in location 1 2 when 1 or 2 modules installed install jumper in location 3 4 when 3 modules installed JP2...

Страница 13: ...s remain off during reset This is normal behavior LED s The table below describes the operating modes LED Color Description GREEN Power is Applied OFF Power is OFF LNK GREEN Link between ports established OFF No Link between ports ACT GREEN Data is active between ports OFF Data is inactive between ports 902 904 Module Jumpers Settings JP1 install jumper in location 1 2 when 1 or 2 modules are inst...

Страница 14: ... the Voltage Input Plug s back into the side header All 10 100BaseT LED s will flash ON Momentarily For fiber optic ports only port 1 will flash momentarily 5 Verify the Power LED stays ON GREEN Note Only 1 plug must be connected to power for minimal operation For redundant power operation V1 and V2 plugs must be connected to separate DC Voltage sources Use wire sizes 16 28 guage Recommended 24V D...

Страница 15: ...s can run a drain wire lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care should be taken to limit the penetration of the outer skin by less than 1 4 in Failure to do so may cause irreversible damage to the internal components of the switch Note Before applying power to the grounded switch you must us...

Страница 16: ...Rev050908 16 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications ...

Страница 17: ...g a port to port connection on the same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure the Error LED remains OFF 3 seconds after initial power up 3 Verify that Link LED s are ON for connected ports 4 Verify straight through cabling used between stations 5 Verify cabling pin outs inte...

Страница 18: ...orage Temperature 20o C to 85o C 0 F to 185o F Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration Bulkhead Mounting Shock 200g 10ms Vibration 1g 10 500Hz 3 axis Seismic 20g 5 200Hz 15s Reliability MTBF 1M Hours measured Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Fiber Singlemode 7 10 125µm Fiber Fiber Trans...

Страница 19: ...rdous Locations Class I Zone 2 Group IIC T4A EMI EN50081 1 1992 EN55022 Class A FCC Part 15 Class A EMS EN55024 1998 EN61000 4 2 1995 EN61000 4 3 1995 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1995 Note Shielded cables must be used to meet emission standards GOST R Certified ...

Страница 20: ...mode fiber 904FXE XX YY Four ports 100BaseFX singlemode fiber Where XX is ST for ST style fiber connector SC for SC style fiber connector Where YY is 15 for 15km max fiber segment length 40 for 40km max fiber segment length 80 for 80km max fiber segment length Warranty Effective January 1 2008 all N TRON products carry a 3 year limited warranty from the date of purchase Contact Support Information...

Страница 21: ...IES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATIO...