NAMC-EXT – Technical Reference Manual
NAMC-EXT NAMC-EXT-PS AMC Extender Module Technical Reference Manual V1.6 HW Revision 1.5
Страница 1: ...NAMC EXT Technical Reference Manual NAMC EXT NAMC EXT PS AMC Extender Module Technical Reference Manual V1 6 HW Revision 1 5...
Страница 2: ...nical Reference Manual Version 1 6 N A T GmbH 2 The NAMC EXT has been designed by N A T GmbH Konrad Zuse Platz 9 D 53227 Bonn Oberkassel Phone 49 228 965 864 0 Fax 49 228 965 864 10 Internet http www...
Страница 3: ...ect damages including lost profits lost savings delays or interruptions in the flow of business activities including but not limited to special incidental consequential or other similar damages arisin...
Страница 4: ...S AND WIRE BRIDGES 15 4 2 1 J1 JP1 AMC Connectors 16 4 2 2 Jumper JP2 18 4 2 3 Jumper JP3 NAMC EXT PS only 18 4 2 4 Wire Bridges 19 4 3 TEST POINTS 19 5 BOARD SPECIFICATIONS 20 6 INSTALLATION 21 6 1 S...
Страница 5: ...Connectors Pin Assignment 16 Table 4 Wire Bridges 19 Table 5 NAMC EXT Board Specifications 20 List of Figures NAMC EXT 7 Figure 1 Mechanical Installation in a Chassis 8 Figure 2 NAMC EXT PS Block Diag...
Страница 6: ...ons Abbreviation Description AMC Advanced Mezzanine Card ATCA Advanced Telecommunications Computing Architecture BUT Board Under Test CLK Clock E1 PDH signal data rate 2 048 Mbit s GND Ground H 110 Ti...
Страница 7: ...assembly option the board can be equipped with an on board 3 3V power supply for generating 3 3V Management Power from 12V Payload Power so the module under test can be operated with an external 12V p...
Страница 8: ...ual Version 1 6 N A T GmbH 8 Mechanical installation of the NAMC EXT is shown in the figure below Mechanical Installation in a Chassis Figure 2 For detailed information about the dimensions of the NAT...
Страница 9: ...rcuitry The NAMC EXT PS features an on board 3 3V power supply for generating Management Power from Payload Power so the module under test can be operated with an external 12V power supply only 2 1 Bl...
Страница 10: ...res highlight the position of the important components Depending on the board type it might be that the board does not include all components named in the location diagrams This applies in particular...
Страница 11: ...NAMC EXT Technical Reference Manual Version 1 6 N A T GmbH 11 NAMC EXT Location Diagram bottom left side Figure 5...
Страница 12: ...ence connector JP1 that picks up the AMC and all measuring points are located on the extended part outside the chassis To allow this it is inevitable that the extended area varies from the outlines de...
Страница 13: ...NAMC EXT Technical Reference Manual Version 1 6 N A T GmbH 13 NAMC EXT Dimensions Figure 6...
Страница 14: ...an 10mA each x Power planes for GND payload power and management power x Both power supplies drive signalling LEDs x Both power supplies may be cut by opening wire bridges for current measurements x O...
Страница 15: ...t specified depends on used AMC 4 Fat Pipes Not specified depends on used AMC 5 Not specified depends on used AMC 6 Not specified depends on used AMC 7 Not specified depends on used AMC Extended Conne...
Страница 16: ...There are 2 connectors and 3 wire bridges on the NAMC EXT Connector J1 is a direct connector and fits into the ATCA or PTCA AMC slot Connector JP1 is the socket into which the device under test is pl...
Страница 17: ...59 13 GND GND 158 14 Rx0 Tx19 157 15 Rx0 Tx19 156 16 GND GND 155 17 GA1 Rx19 154 18 PWR Rx19 153 19 GND GND 152 20 Tx1 Tx18 151 21 Tx1 Tx18 150 22 GND GND 149 23 RLINK2_P Rx18 148 24 RLINK2_N Rx18 147...
Страница 18: ...15 57 PWR Tx12 114 58 GND GND 113 59 Tx6 Rx12 112 60 Tx6 Rx12 111 61 GND GND 110 62 Rx6 Tx11 109 63 Rx6 Tx11 108 64 GND GND 107 65 Tx7 Rx11 106 66 Tx7 Rx11 105 67 GND GND 104 68 Rx7 Tx10 103 69 Rx7 Tx...
Страница 19: ...ing of jumper JP3 defines the source of Management Power By default Management Power is taken from the backplane jumper JP3 in the upper position In case there is no Management Power available e g a t...
Страница 20: ...of BR4 are connected to 12V Payload Power it can be used to connect an external power supply to the extender board NAMC EXT PS only The following table gives an overview of the wire bridges and the s...
Страница 21: ...Table 5 NAMC EXT Board Specifications AMC Module Extender for Standard Advanced Mezzanine Cards single width double height Power Consumption NAMC EXT only 3 3V 0 01A typical 12V 0 01A typical Operatin...
Страница 22: ...e to take before turning on or off the power x Take those steps x Finally turn on or off the power x Before touching integrated circuits ensure to take all require precautions for handling electrostat...
Страница 23: ...cts already 6 3 2 Compliance to WEEE Directive Directive 2002 95 EC of the European Commission on Waste Electrical and Electronic Equipment WEEE predicts that every manufacturer of electrical and elec...
Страница 24: ...hone or e mail 6 3 3 Compliance to CE Directive Compliance to the CE Directive is declared A CE sign can be found on the PCB 6 3 4 Product Safety The board complies to EN60950 and UL1950 6 3 5 Complia...
Страница 25: ...NAMC EXT Technical Reference Manual Version 1 6 N A T GmbH 25 7 Known Bugs Restrictions none...
Страница 26: ...6 06 2007 altered naming of signals to be board independent te 1 4 10 06 2008 adapted to HW Release 1 5 te 1 5 14 11 2011 Added chapter 4 4 Dimensions Ks 1 6 17 05 2013 Address phone and fax words upd...