11
3 - Machine Maintenance
In order to keep the extractor running smoothly and reduce the
risk of damage to the machine and subsequent downtime, Mytee
recommends following the maintenance schedule below:
Maintenance Item
Daily
Weekly
Clean and inspect tanks.
X
Clean and inspect hoses.
X
Check and clean internal filters.
X
Check power supply cable.
X
Clean machine with all-purpose cleaner
and cloth.
X
Check spray nozzles.
X
Flush solution system with Mytee
System Maintainer.
X
Inspect vacuum hoses for holes and
loose cuffs.
X
Inspect spray pattern for clogging.
If clogged, remove spray tips and
soak them in a recommended liquid
neutralizer for up to six hours. To
remove spray tip, twist spray tip body
counter-clockwise.
X
Lubricate casters with water resistant
oil.
X
Inspect machine for water leaks and
loose hardware.
X
3.1 - Opening the Unit for Maintenance
To open your extractor for maintenance, use a drill with a 3/8”
bit to remove the bolts holding the body together. Lift up on the
push handle to open the machine like a clam shell.
♦
3.2 - Filter Maintenance
The extractor has a small filter at the top of the vacuum stack in
the recovery tank. This filter should be checked after each use.
♦
3.3 - System Maintainer
Regular flushing of the solution system with Mytee System
Maintainer keeps your extractor running efficiently by removing
hard water scaling that builds up in the system.
How to use System Maintainer:
1. Thoroughly mix System Maintainer with warm water at a 1:1
ratio in a separate container. Pour into your Extractor’s solution
tank.
2. Connect a cleaning tool (upholstery tool, wand, etc.) and
remove the jet(s) in order to prevent clogging from dislodged
mineral build-up.
3. Turn on the Extractor’s pump and run the System Maintainer
solution through the system and into a bucket or receptacle until
you have a solid stream.
4. Let sit for about 5 minutes while the System Maintainer
solution does its job inside your Extractor.
5. Finish running the rest of the solution through the system.
6. Run clean water through the system to flush out any remaining
System Maintainer.
♦
Do not tamper with the set screw on the
pump pressure switch. This can damage the
pressure switch.
Содержание Contractor's Special 2002CS
Страница 13: ...NOTES...
Страница 14: ...Mytee LLC 13655 Stowe Dr Poway CA 92064 www mytee com 2021 Mytee LLC...