Congratulations on your purchase 
of a new towel dryer from Myson

Towel dryer with power supply cable and plug, fi tted 
with 2-pole switch for connection and disconnection. 
The switch has a red lamp that lights up when the towel 
dryer is switched on. Adaptable for fi xed/concealed 
connection to the mains. Delivered with wall brackets 
and screws.

Rated voltage: 230 V 50 Hz. 

For Australia: 230V-240V

Enclosure class: IP 44 
Double insulation 

Installation

Positioning

The appliance must be installed outside the area 
marked 1, see fi gures 1 and 2, in accordance with the 
latest electrical safety regulations and in such a way 
that no controls (button, switch etc.) can be reached by 
a person using the bath or shower.

Wall-mounting and connection

The towel dryer is mounted on a wall with the enclosed 
screws. To avoid injuries to small children the towel 
dryer must be positioned so that the lowest part is at 
least 600 mm above the fl oor. The recommended 
minimum dimensions to other limiting surfaces in the 
vicinity are indicated in fi gure 3.

The wall brackets can be moved to suit any tile joints 
etc. They can be loosened and tightened from the back 
with the screw in the centre of the wall bracket before 
the towel dryer is mounted on the wall, see fi gure 4.
The cover rings are fi tted to conceal the wall screws: 
the cover rings for the feet are turned in position with 
the recess for dismantling facing downwards (5A) and 
then snapped into place, see fi gure 5. The enclosed cover 
ring(s) is/are snapped over the connection housing and 
where appropriate the wall bracket, see fi gure 6.
All the feet and wall brackets can be turned round so 
that the towel dryer can be reversed. The towel dryer 
can then be mounted with the wall bracket and switch 
either at the top or bottom, on the left or right side.

Towel dryer with power supply cable and plug

The towel dryer’s power supply cable with the plug is 
connected to a wall socket.

Towel dryer with power supply cable 
without plug

The electrical installation must be done by an authorised 
electrician. Remove the plug from the power supply 
cable and connect the 2-wire cable to a suitable 
junction box as follows: 

Brown wire = phase 
Blue wire = neutral

Towel dryer with concealed connection

The towel dryer can as an alternative be fi tted with a 
concealed electrical connection. The electrical 
installation must be done by an authorised electrician.

Installation with concealed connection

1.  Remove the cover on the connection housing by  
 

undoing the screws holding the cover in place, fi g 7.

2.  Lift up the connector by means of a pair of pliers, 
 

fi gure 8.

3.  Unscrew the wires from the connector.
4.  Insert the cable or the equivalent from the wall  
 

through the inlet, fi g 9.

 

For connection with wiring tube: replace the fi tted  

 

membrane inlet with the enclosed open inlet.

5.  Mount the towel dryer on the wall.
6.  Connect the incoming wires to the connector.
7.  Press the connector on the switch, fi g 10.
8.  Fit and screw tight the enclosed sealed cover, fi g 11.

Using the towel dryer 

The towel dryer is switched on by pressing the switch. 
The lamp on the switch lights up when the towel dryer 
is switched on. The towel dryer can be left switched on 
permanently without problem. The temperature of the 
towel dryer can vary.

Product care

Only mild detergent should be used to clean and wipe 
the towel dryer.

Miscellaneous

Failure to follow the installation instructions can lead to 
overheating and malfunctioning.
This towel dryer is only intended for the drying of 
textiles washed in water.  
The appliance is not intended for use by young or infi rm 
persons without supervision. Young children should 
be supervised to ensure that they do not play with the 
appliance.
Myson cannot accept responsibility for any damage 
resulting from incorrect use.
If the power supply cable is damaged it must be 
replaced by the same type supplied by Myson, or 
Myson’s representative.
The maximum surface temperature that can be 
achieved on a free surface is 60ºC.

2-year product guarantee

Please contact your supplier if you have any problems 
and for repairs.

Содержание MTK Series

Страница 1: ...f r modell MTK Monterings och brugsanvisning for model MTK Monterings og brukerveiledning for modell MTK Asennus ja k ytt ohje tyypille MTK Installation and operating instructions for model MTK SE DK...

Страница 2: ...2 3 4 5 6 min 100 mm min 50 mm min 50 mm 1 2 7 8 9 10 11 A...

Страница 3: ...ckpropp f rsedd med 2 polig str mbrytare f r till och fr n koppling Str mbrytaren r f rsedd med en lampa som lyser r tt n r handdukstorken r p slagen Anpass ningsbar f r fast dold el anslutning Levere...

Страница 4: ...v gudtag H ndkl det rrer med tilslutningskabel uden stik Tilslutning skal udf res af en autoriseret elinstallat r Fjern stikket p tilslutningskablet og tilslut 2 lederkablet til en egnet kontakt p f l...

Страница 5: ...psel H ndklet rkerens tilkoblingskabel med st psel kobles til et str muttak i veggen H ndklet rker med kabel uten st psel Elektrisk tilkobling m utf res av kvalifisert elektriker Fjern st pselet p ka...

Страница 6: ...a ja osoittaa yl s tai alas Pyyhekuivain ja pistokkeellinen virtajohto Pyyhekuivaimen pistokkeellinen virtajohto kytket n verkkovirran pistorasiaan Pyyhekuivain ja pistokkeeton virtajohto Kiinte n kyt...

Страница 7: ...owel dryer with power supply cable without plug The electrical installation must be done by an authorised electrician Remove the plug from the power supply cable and connect the 2 wire cable to a suit...

Страница 8: ...RE PRODUKTET BIDRAGER DU TIL AT FOREBYGGE EVENTUELLE NEGATIVE INDVIRKNINGER P MILJ ET OG SUNDHEDEN SOM PRODUKTET KAN BIDRAGE TIL HVIS DET KASSERES SOM ALMINDELIGT HUSHOLDNINGSAFFALD OR OPLYSNINGER OM...

Отзывы: