background image

SPECIFICATION OF THESE PRODUCTS WITHOUT PRIOR NOTIFICATION.

IN ACCORDANCE WITH OUR POLICY OF CONTINUAL PRODUCT IMPROVEMENT, WE RESERVE THE RIGHT TO AMEND THE

MYSON MRT1: ROOM TEMPERATURE THERMOSTAT.

N

L

LOAD

4 3

1

HEATING

230V~

Switching Differential:

1.3 

Operating Range:

6 to 30 

Ambient Humidity:

5 to 95% Relative Humidity.

Ambient Temperature:

0 to 50 

Enclosure Protection:

IP20.

Enclosure Insulation:

Class II, (double insulated).

Switch Rating:

15(2.5)A

Supply Voltage:

230V~, 50Hz.

TECHNICAL DATA.

Disconnect mains supply before removing cover.

PRECAUTIONS AGAINST ELECTRIC SHOCK HAZARD.

Installation & maintenance must be carried out by suitably qualified

personnel and in accordance with current IEE wiring regulations.

Function:

Control of room temperature by electrical switching of control circuit.

Construction:

Electro Mechanical Switch.

C.

o

C.

o

C.

o

Pollution Situation:

Normal.

CIRCUIT WIRING DIAGRAM.

Do not mount to unearthed metal or metalised surfaces.

INSTALLATION INSTRUCTION.

Fixed wiring installation must be employed. A class 'A' switch, (having 

contact separation of at least 3mm in all poles) must be incorporated in the fixed wiring as a 
means of disconnecting the supply. Use a fuse rated at 3 amps to protect the system.

Installation Details:

See wiring diagram below and installation instructions overleaf.

SC1959: Revision 2.

MYSON  LTD, EASTERN AVENUE, 

SALES OFFICE No.: 0845 402 3434

TYNE & WEAR, NE11 0PG

MYSON CONTROLS

TEAM VALLEY, GATESHEAD,

Отзывы: