Myson MPRT RF Скачать руководство пользователя страница 1

OK

H

M

L

HEAT

TIMES

PRESS TO ALTER YOUR HEATING TIMES

PRESS TO DEACTIVATE HEATING, OR HOLD

FOR 5 SECONDS FOR MANUAL OVERRIDE

PRESS FOR 1 HOUR OF HIGH TEMPERATURE

PRESS TO ALTER YOUR “HIGH” TEMPERATURE

PRESS BOTH TOGETHER TO SET/VIEW CLOCK

PRESS TO ALTER YOUR “MID” TEMPERATURE

PRESS TO ALTER YOUR “LOW” TEMPERATURE

OFF

MAN

1 Hr

High Setting

Current

Temp

0

2

4

6

8 10 12 14 16 18 20 22 24

+

MPRT RF

WIRELESS PROGRAMMABLE THERMOSTAT

The MPRT RF consists of a room unit and a relay box.
The Room Unit senses the room temperature and if heat is called 
for, it transmits a radio signal to the relay box which in turn 
activates the heating.

WIRING THE RELAY BOX.

The relay box is powered by 230V ac, 50Hz. 
The figure below shows both low voltage and 230V ac wiring op-
tions for switching the heating equipment.

WARNING:

 

Installation and maintenance to be carried out 

only by suitably qualified personnel and in accordance with cur-
rent IEE wiring regulations.

ROOM UNIT

RELAY BOX

INSTALLATION INSTRUCTION

C

-

1 L N

C 1 L N

O

C

C 1 L N

N

L

230V ac, 50 Hz

input power

input power

To heating
equipment

230V ac, 50 Hz

L

O

C

HEATING
EQUIPMENT

C

-

1 L N

C 1 L N

O

C

C 1 L N

N

L

230V ac, 50 Hz

input power

input power

To heating
equipment

230V ac, 50 Hz

L

O

C

HEATING
EQUIPMENT

Volt  Free/Low Voltage  Switching  of 

Heating Equipment.

C

-

1 L N

C 1 L N

O

C

C 1 L N

N

L

230V ac, 50 Hz

input power

input power

To heating
equipment

230V ac, 50 Hz

L

O

C

HEATING
EQUIPMENT

230V ac Switching of Heating Equipment

ACTIVATING THE ROOM UNIT

Release the cover from the base by pressing at the arrow.
Remove the plastic strip which is preventing the battery connec-
tion in the battery compartment.

The LCD should display as shown below.
Reassemble the cover to the base. 

PRESS HERE

LOCATING THE ROOM UNIT

The room unit can be mounted on its plastic stand and placed on 
a sideboard or other item of furniture. Alternatively it can be wall 
mounted using the two screws provided.
WHEREVER the Room Unit is mounted/used it should be out of 
direct sunlight, out of draughts, and clear of any heat source (e.g. 
radiators, fires or electronic equipment). For optimum use the unit 
should be sited between 1 and 1.5metres from the floor.

MON

 TUE WED

THU FRI SAT SUN

High Setting

Current

Temp

0

2

4

6

8 10 12 14 16 18 20 22 24

MON TUE WED THU FRI SAT SUN

0

2

4

6

8 10 12 14 16 18 20 22 24

High Setting

Current
Time

MON TUE WED
THU FRI SAT SUN

TO ACCEPT & CONTINUE PRESS OK 
TO CHANGE VALUE PRESS   OR  

TO ACCEPT & CONTINUE PRESS OK 
TO CHANGE VALUE PRESS   OR  

FOR LOW PRESS “L”, FOR MEDIUM PRESS “M”, FOR HIGH PRESS “H”
TO ACCEPT & CONTINUE PRESS OK

  

Low Setting

Current

Temp

0

2

4

6

8 10 12 14 16 18 20 22 24

12 14 16 18 20 22 24

 SAT SUN

SMART START

12 14 16 18 20 22 24

 SAT SUN

SMART START

0

2

4

6

8 10

0

2

4

6

8 10

0

2

4

6

8 10

0

2

4

6

8 10

OK

H

M

L

HEAT
TIMES

PRESS TO ALTER YOUR HEATING TIMES

PRESS TO DEACTIVATE HEATING, OR HOLD

FOR 5 SECONDS FOR MANUAL OVERRIDE

PRESS FOR 1 HOUR OF HIGH TEMPERATURE

PRESS TO ALTER YOUR “HIGH” TEMPERATURE

PRESS BOTH TOGETHER TO SET/VIEW CLOCK

PRESS TO ALTER YOUR “MID” TEMPERATURE

PRESS TO ALTER YOUR “LOW” TEMPERATURE

OFF
MAN

1 Hr

High Setting

Current

Temp

0

2

4

6

8 10 12 14 16 18 20 22 24

OK

H

M

L

HEAT
TIMES

PRESS TO ALTER YOUR HEATING TIMES

PRESS TO DEACTIVATE HEATING, OR HOLD

FOR 5 SECONDS FOR MANUAL OVERRIDE

PRESS FOR 1 HOUR OF HIGH TEMPERATURE

PRESS TO ALTER YOUR “HIGH” TEMPERATURE

PRESS BOTH TOGETHER TO SET/VIEW CLOCK

PRESS TO ALTER YOUR “MID” TEMPERATURE

PRESS TO ALTER YOUR “LOW” TEMPERATURE

OFF
MAN

1 Hr

High Setting

Current

Temp

0

2

4

6

8 10 12 14 16 18 20 22 24

(1.0 - 1.5) m

Отзывы: