SCO OpenServer
Manual No. 775079
5-11
5
S
C
O
Updating a Previously Installed Driver
To install the Mylex Disk Array Controller into an existing system to replace
an older version of the driver, perform the following procedure:
1. Make sure you are in single-user mode (init 1), then install the Mylex
mdac
drivers by running the
installpkg
utility. Insert the “Software Kit
SCO OpenServer Driver diskette.”
# init 1
# installpkg
2. When the message prompt asks for a package name, type
mdac
.
Please enter the names of the packages you
wish to install, or q to quit:
mdac
3. A message prompt will advise you that a
mdac
is already installed and
will ask you to confirm that you want to replace it. Type
y
for yes.
There is already a mdac installed.
Do you want to replace it with the version
in madac? (y/n/q):
y
4. Rebuild SCO UNIX kernel.
# cd /etc/conf/cf.d
# ./link_unix
5. Reboot the system to invoke the new kernel.
Tuning SCO for Maximum Performance
Best system performance can be achieved when using the Mylex Disk Array
Controller SCO UNIX
mdac
driver by fine-tuning certain UNIX parameters.
To perform this system tune-up, use the
scoadmin
utility. Select
Hardware/
Kernel manager.
Under the Kernel option select
Tune Parameters
. The
SDSKOUT parameter is located under
Miscellaneous device drives and
hardware parameters
and the NMPBUF parameters is located under
Buffers
management.
Refer to the SCO UNIX on-line documentation for
information on the
scoadmin
utility.
Содержание PCI Disk Array Controller Drivers 08P4100
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 7: ...2 3 4 5 6 7 8 NetWare Windows NT Windows 2000 SCO OpenServer UnixWare Solaris Linux...
Страница 8: ...vi PCI Disk Array Controller Drivers Manual...
Страница 84: ...Changing the Controller Configuration 6 12 Manual No 775079 6 U N I X W A R E...
Страница 94: ...Installing the Disk Array Controller Drivers 8 2 PCI Disk Array Controller Drivers Manual...
Страница 99: ......
Страница 100: ......