Enable Spanning in GAM
4-44
GAM Client User’s Guide
• In GAM more than one system drive can be defined on a single drive
pack; a system drive can also span 16 packs.
• The minimum size of a system drive is 8MB. The maximum is 2 TB.
• Up to 32 system drives can be created. Each system drive has its own
write policy (write-back or write-through).
Enable Spanning in GAM
1. Using a text editor application (such as Notepad), open the gam2cl.ini
file.
2. Scroll to the Enable_System_Drive_Span=0 parameter and set the
parameter to 1 (default value =0).
3. Save and close the gam2cl.ini file.
Configuring a Spanned Disk Array
1. Open RAID Assist by clicking
Administration->RAID Assist
on the
menu bar or the RAID Assist icon as shown in Figure 4-7.
2. The RAID Assist “Welcome” dialog box displays (Figure 4-8).
3. Click the Manual Configuration button.
4. Click the Edit Configuration button.
☛
Note
Automatic and Assisted configuration options do not
allow spanning.
5. To create a JBOD or RAID0 connect at least four drives of the same
size to a controller. To create a RAID 1, RAID 3, RAID 5, or
RAID 0+1, connect at least six drives of the same size to a controller.
Select physical drives from the drive packs to create a spanned array.
Remember to use the same number of devices in each Array or
spanning will not be utilized. Figure 4-41 shows the creation of two
arrays each having three equal sized disk drives.
Содержание Global Array Manager
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 58: ...For More Information 3 38 GAM Client User s Guide...
Страница 106: ...Saving a Configuration to Disk 4 48 GAM Client User s Guide...
Страница 138: ...Battery Backup Unit Monitoring and Maintenance 5 32 GAM Client User s Guide...
Страница 204: ...Glossary Glossary 28 GAM Client User s Guide...
Страница 211: ......
Страница 212: ......