![Myenergi zappi Series Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/myenergi/zappi-series/zappi-series_operation-and-installation-manual_1862235018.webp)
zappi
operation and installation manual
19
Menus
Advanced Menu
Advanced Menu Options
Description
Supply Grid…
Phase:
Set the supply phase to use for this device
– see
page 21 for more information
Device Limit:
Set the maximum available supply current to be drawn
by the
zappi
– see
information
Export Margin:
Minimum level of export power which is maintained
when
zappi
is diverting surplus power
– see
Grid Limit:
Maximum grid import power limit. When charging, the
charge power is reduced to keep import below this
level. This also applies when boosting
– see
Battery:
Sets the mode for managing power when a battery
system is present in the installation. See
(page 32) for more information.
Net Phases:
When set to ON will net the imports and exports across
phases allowing surplus power from one phase to be
used on a different phase.
– see
(page 21) for more information.
CT Config…
CTINT:
Internal CT, used to configure a group limit. See
CT1:
Set the function of CT1 input
See
(page 22) for more details.
CT2:
Set the function of CT2 input
See
(page 22) for more details.
eSense Input…
Disabled
eSense input is disabled
Boost
If the eSense input is live,
zappi
will boost the charge
–
see
Boost Timer Enable
zappi
will boost the charge if eSense is live AND the
boost timer is set to operate at that time.
see
page 23
Compatibility…
PF Responsive:
zappi
will adapt to EV's with poor power factor (e.g.
Renault Zoe).
Min PWM:
Control Pilot PWM minimum limit
Power Factor:
When PF Responsive is ON, the measured power factor
must be better than this set value to enable lower
charging current set by Min PWM
End Charge Delay:
Charge Complete status is delayed by this time to allow
access to the vehicle without starting a new charge
session
Infinite PWM:
Keeps
zappi
ready to restart charge after charge is
complete
– this is needed on some EV's when the user
wants to preheat the vehicle in morning
Menu
Passcode…
The code required to access the Advanced menu