mychefcooking.com
PRODUCT MANUAL iBAKE MAX - DT.MP.IBM.2202.2
60
Housing for MyCare detergent
The 20GN 1/1 and 20GN 2/1 models must use 4 tablets to ensure proper cleaning, due to
the much larger chamber size.
Before starting any cleaning process except rinsing, make sure that the
detergent tablet has been inserted into the oven.
To insert the detergent tablet into the chamber, it is essential to stop the
fan. It is important not to insert the detergent while it is in operation in order
to prevent the detergent from being carried away by the air current, which
could endanger the user's health.
The duration of the specified self-cleaning programmes does not take into
account a possible cooling of the chamber.
Once the automatic process has started, do not open the door under any circumstances, as
the chemicals used for cleaning and steam may escape. This would pose a risk of corrosion
and burns.
Never open the oven door during an automatic cleaning process.
During the execution of a washing programme, it may be necessary to interrupt the
programme due to an emergency. In this case, pressing the circular button START/STOP
will stop the programme and perform a rinse to remove all detergent from the chamber.