5.
INSTALLATION
5.1.
Electrical connection
Check that the voltage at the point where the oven is to be connected coincides with the
operating voltage of the appliance.
The following table indicates the electrical characteristics of each of the devices:
Voltage
Power (kW)
Current (A)
Cable cross-section
(mm
2
)
16 600 x 400
400/3L+N/50-60
34,7
51,7
10,00
230/3L/50-60
34,7
89,9
25,00
Table 2. Electrical connection characteristics
Before carrying out any electrical work, make sure that there is no electrical current at the
connection point of the appliance.
The appliance must be connected to the mains via an all-pole circuit breaker with a contact
opening distance of more than 3mm. Also install a class A residual current device and an
overcurrent protection.
Always ensure effective grounding.
Connect the device to an equipotential bonding system
using
the
contact
specially provided for this purpose (see equipotential sign on the bottom right-hand side of
the device).
Connection to an equipotential bonding system ensures additional safety
in the event of simultaneous earth leakage and differential failure.
The wiring and other safety devices used for the electrical installation must have the
appropriate cross-section for the appliance in question.
Always comply with the applicable regulations for connecting the appliance
to the low-voltage network.
Before starting the electrical installation, check that the electrical requirements of the oven
and the power supply are the same.