background image

Data bits          :    8 bits 
Stop bit            :    1 bit 
Parity                :    none   
 
When work mode “

SCI.3”

 is selected and the scales “

DATA

” key is pressed or the carriage return 

(0d  hex)  is  received,  the  HD  shipping  scale  will  transmit  the  appropriate  weight,  unit,  stability, 
over/down or low voltage message through computers serial port continuously. 

Baud rate        :    9600bps 
Start bit            :    1 bit 
Data bits          :    8 bits 
Stop bit            :    1 bit 
Parity                :    none   

 

 

(2) 

The scale transmits 14 bytes ASCII data each time: 

The details are as follows: 

Byte1.

   

:

” (colon), starting byte 

Byte2.    “

W

” the following 7 bytes (3 through 9) are weight; 

M

 

the following 7 bytes (3 through 9) are messages 

Byte3.    “

“ Byte 4 through Byte 9 are negative weight; 

 

” Byte 4 through Byte 9 are positive weight or other message 

Byte4.    Current weight or other message 

Byte5.    Current weight or other message 
Byte6.    Current weight or other message 
Byte7.    Current weight or other message 
Byte8.    Current weight or other message 
Byte9.    Current weight or other message 
Byte10.11.    “

lb

 

the weight unit is lb; 

                      “

kg

” the weight unit is kg 

Byte12.    “

S

” the readings are stable; 

  “

 

” the readings are unstable 

Byte13.    “

L

” low voltage 

 

” normal voltage 

Byte14.    Carriage Return (0d hex) 
 

 

(3) 

RS-232 connect between HD scale and Host : 

Scale--------------------------Cable-----------------------Host 
(DB9 female)-----------(DB9 male)-(DB9 female)-------(DB9 male) 
TXD     2----------------2------------------2-------------2 RXD 
RXD     3----------------3------------------3-------------3 TXD 
GND     5----------------5------------------5-------------5 GND 
DSR     4----------------4------------------4-------------4 DTR 
DTR     6----------------6------------------6-------------6 DSR 
CTS     7----------------7------------------7-------------7 RTS 
RTS     8----------------8------------------8-------------8 CTS 
NC      1----------------1------------------1-------------1  
NC      9----------------9------------------9-------------9 

***Note: HD scale DB9 female’s pin4 and pin6 is shorted, pin7 and pin8 is shorted! 

Содержание HD150

Страница 1: ...My Weigh HD Series Scales Manual ...

Страница 2: ...all mounting kit This HD Series scale is compatible with most UPS and other shipping software through the built in RS 232 port Please contact your software vendor for all computer hookup operation and installation related questions More information regarding RS 232 connectivity can be found in the Advanced Operating Instructions within Section 4 of this manual Notice 1 Press ON OFF key to turn on ...

Страница 3: ...ork mode please use the following steps Step1 Press down and hold the M key until the indicator displays SCI x x 0 or 1or 2 or 3 Step2 Press the M or D key to change the x value the display will flash the x value when it is changed press the T key for confirmation the x will then stop flashing Step3 Press the key to exit programming When work mode SCI 1 Serial Communication Interface transmitting ...

Страница 4: ... Byte 9 are negative weight Byte 4 through Byte 9 are positive weight or other message Byte4 Current weight or other message Byte5 Current weight or other message Byte6 Current weight or other message Byte7 Current weight or other message Byte8 Current weight or other message Byte9 Current weight or other message Byte10 11 lb the weight unit is lb kg the weight unit is kg Byte12 S the readings are...

Страница 5: ... 5 After the reading 0 00 becomes stable the scale will display CAL F place the correct standard weight s on the platform 60kg standard weight for HD150 120kg standard weight for HD300 press the T key the F in CAL F will flash 6 After the readings 60 00 for HD150 or 120 00 for HD300 are stable the indicator will display CAL 0 remove the weight s from the platform press the T key the 0 in CAL 0 wil...

Страница 6: ...er North South of Denver 13 12 Connecticut 16 Delaware 15 Florida West Palm Beach North South of West Palm Beach 11 10 Georgia 12 Hawaii 9 Mississippi Kosciusko North South of Kosciusko Missouri North of Springfield Springfield South Montana Helena North South of Helena Nebraska Nevada New Hampshire New Jersey New Mexico New York Albany North South of Albany North Carolina Raliegh North South of R...

Страница 7: ...chigan Northwest of Lake Michigan Southeast of Lake Michigan 18 17 Minnesota 18 Salem North Between Oakridge Salem South of Oakridge Pennsylvania Rhode Island South Carolina South Dakota Tennessee Texas Northeast of Colorado River Southwest of Colorado River Utah Vermont Virginia Washington DC Washington State West Virginia Wisconsin Green Bay North South of Green Bay Wyoming North of Casper Caspe...

Страница 8: ...Country Code Country Code Albania 8 Latvia 11 Andorra 8 Liechtenstein 9 ...

Страница 9: ...inland 12 Romania 8 France Lyon North South of Lyon 9 8 Russia Moscow North South of Moscow 12 10 Germany 01 2 3 41 25 61725 10 01 2 10 9 Spain Madrid North South of Madrid 8 7 Gibraltar 7 Serbia and Montenegro 8 Greece 7 Slovakia 9 Holy See Vatican City 8 Slovenia 9 Hungary 9 San Marino 8 Iceland 12 Sweden North of Stockholm Stockholm South 12 11 Ireland 10 Switzerland 9 Italy 8 Ukraine 9 United ...

Страница 10: ...edail Fleur de lys Fleur de lys South 11 10 9 Nova Scotia 8 Ontario North of Nakina Nakina South 10 9 Prince Edward Island Quebec North of Schefferville Between Schefferville Sept Iles Sept Iles South Saskatchewan North of Prince Albert Prince Albert South Northwest Territories Echo bay North South of Echo bay Nunavut Territory Victoria Island North Between Victoria Island Baker Lake South of Bake...

Страница 11: ...oad protection screws Battery compartment and it s cover Fig1 Bottom view of the scale Indicator s outline and placement positioning 012 3 4 5 50 6 7 8 12 9 4 1 5 A 5 BA A 5 BCDE A Hanging on wall Placed on a table Outline Fig 2 Indicator s outline and placement positioning ...

Отзывы: