Installation Manual

 

 

 

 

Type

HDR DIN rail power supply

Series

HDR-15, HDR-30, HDR-60, HDR-100

 

HDR-15-5 

 

INPUT: 100-240VAC 0.5A 50/60Hz        OUTPUT: 5V 2.4A 

HDR-15-12   

INPUT: 100-240VAC 0.5A 50/60Hz    OUTPUT: 12V 1.25A 

HDR-15-15   

INPUT: 100-240VAC 0.5A 50/60Hz    OUTPUT: 15V 1.0A 

HDR-15-24   

INPUT: 100-240VAC 0.5A 50/60Hz    OUTPUT: 24V 0.63A 

HDR-15-48   

INPUT: 100-240VAC 0.5A 50/60Hz    OUTPUT: 48V 0.32A 

HDR-30-5 

 

INPUT: 100-240VAC 0.88A 50/60Hz      OUTPUT: 5V 3.0A 

HDR-30-12   

INPUT: 100-240VAC 0.88A 50/60Hz   OUTPUT: 12V 2.0A 

HDR-30-15   

INPUT: 100-240VAC 0.88A 50/60Hz   OUTPUT: 15V 2.0A 

HDR-30-24   

INPUT: 100-240VAC 0.88A 50/60Hz   OUTPUT: 24V 1.5A 

HDR-30-48   

INPUT: 100-240VAC 0.88A 50/60Hz   OUTPUT: 48V 0.75A 

HDR-60-5 

 

INPUT: 100-240VAC 1.8A 50/60Hz        OUTPUT: 5V 6.5A 

HDR-60-12   

INPUT: 100-240VAC 1.8A 50/60Hz    OUTPUT: 12V 4.5A 

HDR-60-15   

INPUT: 100-240VAC 1.8A 50/60Hz    OUTPUT: 15V 4.0A 

HDR-60-24   

INPUT: 100-240VAC 1.8A 50/60Hz    OUTPUT: 24V 2.5A 

HDR-60-48   

INPUT: 100-240VAC 1.8A 50/60Hz    OUTPUT: 48V 1.25A 

HDR-100-12  

INPUT: 100-240VAC 3.0A 50/60Hz    OUTPUT: 12V 7.1A 

HDR-100-15  

INPUT: 100-240VAC 3.0A 50/60Hz    OUTPUT: 15V 6.13A 

HDR-100-24  

INPUT: 100-240VAC 3.0A 50/60Hz    OUTPUT: 24V 3.83A 

HDR-100-48  

INPUT: 100-240VAC 3.0A 50/60Hz    OUTPUT: 48V 1.92A 

HDR-100-12N 

INPUT: 100-240VAC 3.0A 50/60Hz    OUTPUT: 12V 7.5A 

HDR-100-15N 

INPUT: 100-240VAC 3.0A 50/60Hz    OUTPUT: 15V 6.5A 

HDR-100-24N 

INPUT: 100-240VAC 3.0A 50/60Hz    OUTPUT: 24V 4.2A 

HDR-100-48N 

INPUT: 100-240VAC 3.0A 50/60Hz    OUTPUT: 48V 2.1A 

 

 

 

Introduction 

HDR is a DIN rail power supply series with ultra slim appearance and full range AC input (100-240Vac). The series 
conforms to EN6100-3-2, the norm the European Union regulates for harmonic current. With plastic housing, it can 
effectively prevent user from electric hazards. Like other Mean Well’s DIN series, they can be mounted on a TS35 
Standard DIN rail. 

 

 

Installation 

1

Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit 

in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a 
heat source. 

2

The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on 

the top. Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not 
allowed. 

 
 
 
 
 